Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C * Salem, Oregon 97305-1398 <br />Office Hours: 8:00-4:30 * Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />DATE/TIHE <br />TYPE <br />OCCUPANCY <br /> <br /> I~HUFACTURED DWELLING PERHIT <br />= 1~2/11/99 14=25 PERHTT NO = 98-~i)825 <br />: ge~ flanufactured 9~elli~g STATUS : ISSU~ <br />: R-3 ISS~D : ~11/1998 <br /> TO EXPIRE ~ ~8/1~/1998 <br /> P~E 3 <br />cross-sec~innal dimension, or ~h~ shape shall provide an <br />equivalent gripping surface. Hendrails ~hall be mounted <br />be~ween a minimum of ~8 inches and ~ maximum of 38 inches. <br />They shall be c~n~inuous ~he fL~ll length of the s~airs. <br />Enos shall be re~.~rned or sha~[1 ~erP~ina~e in newel pos~s or <br />safe~y <br />(R-214.1) <br />A minimum 3' x ~' landing sh~ll be required on each side of <br />an egress door. The fl~or ~r landing shall not be more <br />~hen one and one-half inches lower than the top of the <br />threshold. (R-212) Excep~ion: The landing on the <br />exterior side of an exterior doorway shall no~ be more than <br />8 and 1/4 inches below the top of the threshold. <br />Po~ches, balconies or raimed floor surfaces located mo)-e <br />than 30 in. above ~he flo~r or qrade shall have guardrail <br />no~ ]ess ~han 3~ inches in heigM~. Requi~'ed guar~rail shall <br />have intermediate rails or ornamental closures which will <br />no~ allow passage of an object 6 in. or more in diameDer. <br />Horizontal spacing between ~he vertical members in required <br />guardrails shall Ge a maximum of 4 inches at the nearest <br />poin~ between the members. (R-214.2) <br /> <br /> <br />