BUILDING PERMIT
<br />DATE/TIME : 03/05/98 07:22 PERMIT NO
<br />TYPE : Resident. addition/alteration STATUS
<br />OCCUPANCY : R 3 ISSUED
<br />CONST TYPE : V N TO EXPIRE
<br />UGB: SITE: PAGE
<br />
<br />98-00835
<br />ISSUED
<br />03/04/1998
<br />08/31/1998
<br /> 2
<br />
<br />PLAN REVIEW COMMENTS AND CONDITIONS
<br />
<br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special:
<br />
<br /> 1. THIS PLAN REVIEW WAS COMPLETED BY R.STEWART ON 3-3-98.
<br /> 2, Approval of submitted plans is not an approval of omissions
<br /> or oversights by this office or of noncompliance with any
<br /> applicable regulations of local government,
<br /> 3, WORK MAY PROCEED only at the direction of the inspector. To
<br /> request an inspection of completed work, call (503)373-4427
<br /> 24-hour inspection line) prior to 7:00 A.M. to receive the
<br /> same day service.
<br /> 4, USE THE INSPECTION CODE NUMBERS WHEN REQUESTING INSPECTIONS:
<br /> 904 REBAR
<br /> 905 TEMPORARY ELECTRICAL SERVICE
<br /> 906 FOOTINGS, Stake property lines and call before pour
<br /> 907 UNDERFLOOR STRUCTURAL, call before adding subfloor
<br /> 908 UNDERFLOOR MECHANICAL, call before adding subfloor
<br /> 909 UNDERFLOOR PLUMBING. call before adding subfloor
<br /> 911 ELECTRICAL SERVICE, service only
<br /> 912 ELECTRICAL PRE-COVER, call before covering
<br /> 913 MECHANICAL PRE-COVER. call before covering
<br /> 914 PLUMBING TOP-OUT, call before covering
<br /> 5. 915 FRAME. call when weather tight, chimney/fireplace
<br /> installed, all backing, blocking, stairs, soffits in
<br /> place, rough plumbing, electrical, mechanical complete,
<br /> truss details posted, flood elevation certification
<br /> submitted.
<br /> 916 INSULATION, call before covered
<br /> 917 DRYWALL, call before taped
<br /> 91B SPECIAL BRACE PANEL, call before covering ABP's, Portal
<br /> Frames, or Shear Walls
<br /> 922 RAIN DRAINS
<br /> 923 WATER SERVICE
<br /> 924 SEWER SERVICE
<br /> 6. 925 GAS PIPING
<br /> 926 FIREPLACE, call for throat inspection
<br /> 930 DWELLING MECHANICAL FINAL
<br /> 931 DWELLING PLUMBING FINAL
<br /> 932 DWELLING ELECTRICAL FINAL
<br /> 999 DWELLING FINAL, call when building is complete and
<br /> ready to occupy.
<br /> 7, ACCEPTABILITY. This plan review covers the addition to and/
<br /> or alteration of an existing structure, This review is not
<br /> intended to prohibit the building inspector from requesting
<br /> an evaluation of the acceptability of existing structural
<br /> members that may appear to be unsafe, Existing construction
<br /> not specifically detailed in the submitted plans and struc-
<br /> tural calculations is beyond the scope of this review,
<br /> B. FINISHED GRADE. Footings shall extend not less than 12
<br /> inches below the finish natural grade. Foundation walls
<br /> shall extend at least 6 inches above the finished grade
<br /> adjacent to the foundation at all points, except 4 inches is
<br /> allowed where masonry veneer is used, [Fig. 403,1a,
<br /> Section 404.1,3]
<br /> 9. ANCHOR BOLTS, Foundation plates shall be bolted to the
<br /> foundation with a minimum 1/2 inch diameter by 10 inch
<br /> anchor bolts embedded at least 7 inches into concrete or
<br /> reinforced masonry and spaced not more than 6 feet apart
<br /> with a minimum of 2 bolts per piece with one bolt within
<br /> 12 inches of the end of each piece, [Fig. 403,1a]
<br />10, UNDERFLOOR VENTILATION, Provide at least one square foot of
<br /> underfloor ventilation for each 1500 square feet of crawl
<br /> space area. The openings shall be covered with a corrosion
<br /> resistant wire mesh, At least one such opening shall be
<br /> provided within 3 feet of each corner of the building,
<br /> Vents may be omitted on one side. [Sec, 409,1]
<br />11. UNDERFLOOR DRAINS, The finished grade oF the underfloor
<br /> surface may be located at the bottom of the footing; however