Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />04/28/98 09:12 PERMIT NO <br />New Commercial STATUS <br />S-5 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />98-02760 <br />ISSUED <br />04/28/1998 <br />10/25/1998 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: <br /> OK AS PER SITE PLAN <br /> <br />Special: <br /> <br /> 1, THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 04/23/98. <br /> 2, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 2. ALLOWABLE AREA, (OSSC Sec 504) <br /> Basic Allowable Area: 12,000 sqft (S-5/II-N) <br /> Proposed: 3,600 sqft <br /> Maximum Height: 55 ft <br /> Proposed: 22 ft <br /> Maximum Stories: 2 <br /> Proposed: 1 <br /> There are four proposed hangars in this area, which Hangars <br /> 12 & 13 are to be built first. The aggregate area for all <br /> four buildings equals 14.400 sq ft. There are 2-yards avail <br /> able. for a 100% increase, therefore, the total square foot- <br /> age of the four hangars are 14,400, less than 18,000 sq ft. <br /> 4. This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA/. <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute. Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board. <br /> 1-202-653-7834 (Voce/TDD) or 1-800-USA-ABLE. Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties, <br /> 5, Local Fire Districts may have additional requirements that <br /> affect this project. You are advised to contact the Fire <br /> District before you proceed. <br /> 6, This is a Plan Review covering the construction of the <br /> above indicated new building. Plans have been reviewed for <br /> compliance with the provisions of the Oregon State <br /> Structural Specialty Code ('94 UBC) 1996 Edition. <br /> ****************** HANGAR UNIT #12 *********************** <br /> 7, OCCUPANCY CLASSIFICATION. (OSSC Sec 311.1) <br /> This building is classified as a Group S. Division 5 <br /> Occupancy: Aircraft hangar where work is limited to exchange <br /> of parts and maintenance requiring no open flame or welding. <br /> 8. TYPE OF CONSTRUCTION, (OSSC Sec 603.1) <br /> This building has been determined to be of Type II-N <br /> construction, <br /> The structural elements, floor construction, wall and <br /> ~ermanent partitions shall be of noncombustible materials. <br /> aterials of construction and fire-resisitve requirements <br /> shall be as specified in Section 601. <br /> 9. SPECIFIC USE PROVISIONS. (OSSC Sec 311.2.2.1) <br /> In areas where aircraft are stored, floor surfaces shall be <br /> of noncombustible, nonabsorbent materials, <br /> Floor shall drain to an approved oil separator or trap <br /> discharging to sewers in accordance with the Plumbing Code, <br /> EXECPTION: Floors may be surfaced or waterproofed with <br /> asphaltic paving materials in areas where <br /> airplanes are stored or operated. <br />10. SPECIFIC HAZARDS. (OSSC Sec 211.8) <br /> Storage and use of flammable and combustible liquids shall <br /> be in accordance with the Fire Code. <br /> Devices generating a glow. spark or flame capable of <br /> igniting flammable vapors shall be install ed such that <br /> sources of ignition are at least 18 inches above the floor <br /> of any room in vJnich Class I flammable liquids or flammable <br /> gases are used or stored. <br />11. CONTACT PERSONS: <br />12. Donald K. Miller. Deputy State Fire Marshal <br /> State of Oregon Fire Marshal <br /> 4760 Portland Rd. NE <br /> Salem, Or. 97305 <br /> <br /> <br />