Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />04/27/98 15:21 PERMIT NO <br />New Commercial STATUS <br />S-5 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-02759 <br />ISSUED <br />04/27/1998 <br />10/24/1998 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: <br /> OK AS PER SITE PLAN <br /> <br />Special: <br /> <br />1. THIS PLAN REVIEW WAS COMPLETED BY M, JONES ON 04/23/98. <br />2, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />2. This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA), <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute. Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board, <br /> 1-202-653-7834 (Voce/TDD) or 1-800-USA-ABLE. Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties. <br />4. Local Fire Districts may have additional requirements that <br /> affect this project. You are advised to contact the Fire <br /> District before you proceed. <br />5, This is a Plan Review covering the construction of the <br /> above indicated new building. Plans have been reviewed for <br /> compliance with the provisions of the Oregon State <br /> Structural Specialty Code ('94 UBC) 1996 Edition, <br /> **~-*************** HANGAR UNIT #11 ******~-****************~* <br />6. OCCUPANCY CLASSIFICATION, (OSSC Sec 311.1) <br /> This building is classified as a Group S, Division 5 <br /> Occupancy: Aircraft hangar where work is limited to exchange <br /> of parts and maintenance requiring no open flame or welding, <br /> 7. TYPE OF CONSTRUCTION. (OSSC Sec 603.1) <br /> This building has been determined to be of Type V-N <br /> construction. <br /> The type of construction classification of V-N is used to <br /> allow for the second Exception in Section 503,3. aggregate <br /> area of two or more buildings on the same property. <br /> By including Norm's Hangars. no exterior fire-resistive wall <br /> construction will be required between the hangars. <br /> 8, ALLOWABLE AREA. (OSSC Sec 504) <br /> Basic Allowable Area: 8,000 sqft (S-5/V-N) <br /> Proposed: 3,600 sqft <br /> Maximum Height: 40 ft <br /> Proposed: 22 ft <br /> Maximum Stories: 2 <br /> Proposed: 1 <br /> Include Norm's 3.600 square foot, Type V-N Hangar No. 10. <br /> (which is west of the proposed Hangar No. 11. for a total of <br /> 7,200 square feet. <br /> No fire-resistive exterior wall is required due to location <br /> on property. <br /> 9. LOCATION ON PROPERTY. (OSSC Sec 502) <br /> Exterior walls shall have fire resistance and opening <br /> protection as set forth in Table 5-A and in accordance with <br /> such additional provisions as are set forth in Chapter 6. <br /> TABLE 5-A for S-5 Occupancy: <br /> Exterior Walls: One-hour noncombustible construction less <br /> than 20 feet. <br /> Openings: Not permitted less than 5 feet and protected less <br /> than 20 feet with three-fourths-hour fire rated <br /> assembly. <br />10. SPECIFIC USE PROVISIONS. (OSSC Sec 311.2,3.1) <br /> In areas where aircraft are stored, floor surfaces shall be <br /> of noncombustible, nonabsorbent materials. <br /> Floor shall drain to an approved oil separator or trap <br /> discharging to sewers in accordance with the Plumbing Code. <br /> EXECPTION: Floors may be surfaced or waterproofed with <br /> asphaltic paving materials in areas where <br /> airplanes are stored or operated. <br />11. SPECIFIC HAZARDS. (OSSC Sec 311,8) <br /> Storage and use of flammable and combustible liquids shall <br /> <br /> <br />