My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1501522
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1501522
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2011 4:24:37 PM
Creation date
10/12/2004 7:10:53 AM
Metadata
Fields
Template:
Permits
Permit Address
250 DETROIT AV S
Permit City
Detroit
Permit Number
555-98-02439
Parcel Number
105E01CB10500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: DT SITE: <br /> <br /> BUILDING PERMIT <br />05/05/98 15:50 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-02439 <br />ISSUED <br />05/05/1998 <br />11/01/1998 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 5 Right: 5 Rear: 15 Special: <br /> <br />1, THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 05/04/98. <br />2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />3, ACCEPTABILITY, This plan review covers the addition to and/ <br /> or alteration of an existing structure, This review is not <br /> intended to prohibit the building inspector from requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe, Existing construction <br /> not specifically detailed in the submitted plans and struc- <br /> tural calculations is beyond the scope of this review. <br />4. DESIGNER RESPONSIBILITY. The plans submitted do not clearly <br /> shew all the required framing details. It is the designer's <br /> responsibility to size all structural members and fasteners <br /> for the appropriate loads and have them shown on the plans. <br /> [Sec, 112,1] <br />5. SMOKE DETECTORS / ALTERATIONS, When alterations, repairs or <br /> additions are made to an existing dwelling, the entire <br /> building shall be provided with smoke detectors located as <br /> required for new dwellings. The smoke detectors are not <br /> required to be interconnected unless other remodeling con- <br /> siderations require removal of the appropriate wall and <br /> ceiling coverings to facilitate interconnecting wi ring. <br /> [Section 316.1,1] <br />6. SMOKE DETECTORS shall be installed in each sleeping room, <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors shall be inter- <br /> connected such that the actuation of one alarm will actuate <br /> all the alarms in the individual unit and shall provide an <br /> alarm which will be audible in all sleeping areas. <br /> [Section 216.1] Smoke detectors shall be 110 volt with <br /> battery back-up, [Sec, 316.2] <br />7, DECORATIVE GAS APPLIANCES shall be listed and installed in <br /> accordance with their listing and the manufacturer's <br /> installation instructions. [Sec. 2205] <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.