DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> DWELLING PERMIT <br />04/14/98 15:19 PERMIT NO <br />New Si ngl e Fami 1 y Dwel 1 ing STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-02118 <br />ISSUED <br />04/14/1998 <br />10/1t/1998 <br />2 <br /> <br /> PlAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 10 Right: 10 Rear: 20 Special: <br /> <br />1, THIS PLAN REVIEW was completed by DWALTERS ON 4/7/98, <br /> This plan was reviewed under the 1996 Edition of the State <br /> of Oregon One and Two Family Dwelling Specialty Code, <br />2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br />2. LOT DRAINAGE. Lots shall be provided with adequate drainage <br /> and shall be graded so as to drain surface water away from <br /> foundation walls. The grade away from foundation walls shall <br /> fall a minimum of 6 inches within the first 10 feet. Where <br /> lot lines, walls or other physical barriers prohibit <br /> 6 inches of fall within 10 feet, drains or other approved <br /> means shall be provided to ensure positive drainage. <br /> [Sec. 401,2] <br />4, GARAGE/CARPORT FLOOR. That area of floor used for the <br /> ~arking of automobiles or other vehicles shall be sloped to <br /> acilitate the movement of liquids to a drain or toward the <br /> main vehicle entry doorway, [Sec. 309.3] <br />5. VAPOR BARRIER, An approved vapor barrier with joints lapped <br /> not less than 12 inches shall be placed between the concrete <br /> floor slab and the base course or subgrade~ Exception: The <br /> vapor barrier may be omitted from detached garages, utility <br /> buildings and other unheated accessory structures, <br /> [Sec, 505.2.2] <br />6. BP. ABP, This structure uses a combination of Brace Wall <br /> Panels (BP) and Alternate Braced Walt Panels (ABP) to meet <br /> the code requirements for lateral wall bracing, Insure that <br /> all BP's are located as indicated on the plans. <br />7. SAFETY GLAZING / AT DOOR, The following shall be considered <br /> specific hazardous locations for the purposes of glazing: <br /> Glazing, in an individual fixed or operable panel <br /> adjacent to a door where the nearest vertical edge is <br /> w~thin a 24 inch arc of the door in a closed position <br /> and whose bottom edge is less than 60 inches above <br /> the floor or walking surface. Exception: Safety <br /> glazing is not required when there is an intervening <br /> wall or other permanent barrier between the door and <br /> the glazing. <br />8. SAFETY GLAZING / TUBS. The following shall be considered <br /> specific hazardous locations for the purposes of glazing. <br /> Glazing in doors and enclosures for hot tubs, whirlpools <br /> saunas, steam rooms, bathtubs, showers; glazing in any <br /> part of a building wall enclosing these compartments <br /> where the bottom edge of the glazing is less than 60 <br /> inches above the drain outlet. <br />9. EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue~ <br /> The window sill height shall not be more than 44 inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet, The minimum net clear opening height shall be 22 <br /> inches, The minimum net clear opening width shall be 20 <br /> inches, Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet, [Sec. 310.2, 310,2.1] <br />10. SMOKE DETECTORS shall be installed qn each sleeping room, <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors shall be inter- <br /> connected such that the actuation of one alarm will actuate <br /> all the alarms in the individual unit and shall provide an <br /> alarm which will be audible in all sleeping areas, <br /> [Section 216,1] Smoke detectors shall be 110 volt with <br /> battery back-up, [Sec, 316~2] <br />11. FUEL-BURNING APPLIANCES shall not be installed in a room <br /> designed as a storage closet~ Furnaces installed in a <br /> <br /> <br />