My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1501355
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1501355
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2013 6:44:43 PM
Creation date
10/12/2004 7:08:38 AM
Metadata
Fields
Template:
Permits
Permit Address
14362 STENBOCK WY NE
Permit City
Aurora
Permit Number
555-98-02171
Parcel Number
041W02D 80003
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />l~/pE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />04/08/98 11:09 <br />Commercial addition/alteration <br />S-5 <br />II-N <br /> <br /> PAGE <br /> 12. This is a Plan Review covering the TENANT IMPROVEMENT in <br /> HANGAR 'A'. UNIT 104-A, at the Aurora Airpark, <br /> Plans have been reviewed for compliance with the provisions <br /> of the 1996 Edition ('94 UBC) Oregon Structural Specialty <br /> Code. <br /> TheTeneant Improvement includes: <br /> a) 15' x 10' Office. <br /> b) 5' x 4' Storage Room. <br /> c) 5' x 6' Restroom, <br /> Approximately 200 square feet. <br /> 13. TYPE OF CONSTRUCTION, (OSSC Sec 603,1) <br /> The existing building was classified as Type II-N <br /> construction, therefore, materials used shall be as follows: <br /> 1, The structural elements - noncombustible materials. <br /> 2. Floor construction - noncombustible materials, provided <br /> however, that a w~od surface or finish may be applied <br /> over such noncombustible materials. <br /> 2. Walls and permanent partitions - noncombustible materials <br /> 4. Materials of construction and fire-resistive requirements <br /> shall be as specified in Section 601. <br /> 5. For requirements due to occupancy, see Chapter 3. <br /> 14. EXCEPTION TO TABLE 6-A. (OSSC Sec 601.5.2.1) <br /> OFFICES, <br /> Interior nonload-bearing partitions dividing portions of <br /> stores, offices or similar spaces occupied by one tenant <br /> only and which do not establish a corridor serving an <br /> occupant load that would require it to be fire-resistive <br /> construction under the provisions of Section 1005.7 may be <br /> constructed of: <br /> 1) Noncombustible material. <br /> 2) Fire-retardant-treated wood, <br /> 3) One-hour fire-resistive construction, <br />15. OCCUPANCY SEPAPJ~TION. (OSSC Sec 302.4) <br /> When a building is used for more than one occupancy purpose, <br /> each part of the building comprising a distinct "occupancy" <br /> as described in Section 201 shall be separated from ahy <br /> other occupancy as specified in Section 202.4, <br /> EXCEPTION: 2, The following occupancies need not be <br /> separated from the uses to which they are accessory: <br /> 2,1 Assembly rooms having a floor area of not over 750 sq ft <br /> 2,2 Administrative and clerial offices and similar rooms <br /> which do not exceed 25 percent of the floor area of the <br /> major use when not related to Group H, Division 2 and <br /> Group H, Division 3 Occupancies, <br />16. SPECIAL HAZARDS, (OSSC Sec 304.7) <br /> Storage and use of flammable and combustible liquids shall <br /> be in accordance with the Fire Code, <br /> Devices generating a glow, spark or flame capable of <br /> igniting flammable vapors shall be installed such that <br /> sources of ignition are at least 18 inches above the floor <br /> of any room in which Class I flammable liquids of flammable <br /> gases are used or stored. <br />17, CONTACT PERSONS: <br />18, Donald K. Miller, Deputy State Fire Marshal <br /> State of Oregon Fire Marshal <br /> 4760 Portland Rd. NE <br /> Salem, Or. 97205 <br /> (502) 378-4917 <br /> FAX 273-1825 <br />19. Dick Johnson, Fire Marshal <br /> Aurora RFPD (Marion/Clackamas) <br /> PO Box 100 <br /> Aurora. OR 97002 <br /> PH: (503) 678-1282 <br /> <br />PERMIT NO 98-02171 <br />STATUS ISSUED <br />ISSUED 04/08/1998 <br />TO EXPIRE 10/05/1998 <br /> 3 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.