Laserfiche WebLink
Carlson Testing, Inc. <br /> <br />August 8, 1997 <br />CTI #97-G1106 <br /> <br />Construction Inspection & Relrlted Tests <br /> Geotechntcal Consuiting <br /> <br /> P.O. Box 23814 <br />Tigard, Oregon 97281 <br />Phone (503) 684-3460 <br />FAX (50a) 684-O954 <br /> <br />Craig Robert~ and Bob Alton <br />24085 and 24075 Butteville Road <br />Aurora, OR 97002 <br /> <br />ENGINEER'S RESPONSE TO MARION COUNTY FLOODPLAIN PERMIT AND ENGINEERING REVIEW <br />ROBERTS AND ALTON RESIDENCES <br />BUTTEVILLE, OREGON <br /> <br />This letter is in response to the county's review of our geotechnical review of slope failure letter dated <br />June 20, 1997. The Roberts and Alton residences are located along the Willamette River and are <br />within the floodplain. Prier to approval, it is our understanding that the proposed slope stabilization <br />work must be shown that it is anchored in such a manner to prevent flotation, collapse or lateral <br />movement. The stabilization measures must also be shown to be in compliance with Section <br />178.060(c)(2). <br /> <br />From our review of Section 178.060(c){2) it appears that the only major concern is that the structure <br />does not reduce the volume of the flood plain. Since the stabilization measures will incorporate <br />substantially less volume than what natural slope slid into the river two winters ago, it is our opinion <br />that there is no net volume reduction. The approximate old slope configuration as drawn from the <br />homeowners recollections is shown on sheet 1 attached. The top of the proposed structure is about <br />elevation 89 feet MSL. <br /> <br /> The structure will be a driven mw of steel "H' HP10x42 piles emplaced 30 feet deep and retaining <br /> a maximum of 10 feet of free draining gravel that is gently sloped. The backfill is lagged between <br /> piles spaced 10 feet center to center using Hollowcore 4CF8 extruded concrete panels (4.7 strand). <br /> Since the material used have specific gravities much greater than water and no trapped air spaces, <br /> flotation or anchoring is not a problem. The geotschnical stabilization of the riverbank is primarily <br /> from the gravel emplacement. The soldier piles are placed merely to retain the toe of the gravel. <br /> From our check the steel soildier piles have an allowable moment of 78,120 ft-lbs and the actual <br />' moment from the lateral gravel load is about 41,574 fi-lbs. The hollowcore panels selected have an <br /> actual average lateral pressure of about 156 Ib/ft= which is acceptable for a span of up to 16 feet. <br /> Our calculations are shown in the attached sheets I and 2. The panel manufacturers specifications <br /> are also attached. If further verification is necessary, such as to determine deflections, then we <br /> recommend that a structural engineer be consulted. In our opinion, the proposed structure meets the <br /> county requirements and will adequately resist lateral movement. <br /> <br />Our reports pertain to the material tested/inspected only. Information contained herein is n°t to be <br />reproduced, except in full, without prior authorization from this office. If there are any questior, s, <br /> <br />please do not hesitate to contact this office. <br /> <br />Respectfully submitted, <br />CARLSON TESTING, INC/~.~ <br /> <br /> o E o. // <br /> <br /> <br />