SESPNEW - 1473975
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
97-XXXXX
>
SESPNEW - 1473975
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2010 10:54:32 AM
Creation date
8/19/2004 12:49:39 PM
Metadata
Fields
Template:
Permits
Permit Address
8340 DARLEY RD SE
Permit City
Aumsville
Permit Number
555-97-03555
Parcel Number
092W14D 00700
Permit Type
SESPNEW
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon 97305-1398 <br />Office Hours: 8:00-4:30 · Pllmle: (503} 588-5147 · 24-HR Inspection Une: (503) 373-4427 <br /> <br />12s13 <br /> <br />8EPTIC PER~IT <br /> <br />~'I~i~XT MO s 77-83555 <br /> s X~U~ <br /> s 06/03/1997 <br />~ E~IRE s 06/93/1999 <br />~ 2 <br /> <br /> SEPTIC PERHIT <br /> <br />This property was previously evaluated 1~/25/197B for the feasibility to install a <br />septic system fora RESIDENTIAL building site. Based on the results of this study, site <br />approval was granted. The approval is site specific to the area tested, and the septic <br />system must be located in the immediate area of the test pits, unless otherwise authorized <br />by this office. A new site evaluation may be required if the system is proposed for a <br />different area on the property, <br /> <br />This approval was given on the basis that the lot or parcel will not be further partitioned <br />or subdivided and that conditions on this property and on adjacent properties are not altered <br />in any manner which would prohibit the issuance of a permit. Soils in the approved area <br />shall not be altered by cutting, fillin0, or other developmental activities which would <br />impede the successful operation of the initial or replacement absorption systems. Failure <br />to comply with the above items may void this approval. <br /> <br />The site evaluation approval runs with the land, but the permit is non-transferable and non- <br />refundable. <br /> <br />Keep this document with your records. Show this permit to the septic installer prior to <br />~pstall~tion of the system. Any deviation from the approved plan must have prior approval from <br />:his of Tice. <br /> <br />The following construction specifications shall apply to the installation of the initial <br />septic systeml <br /> <br /> TYPE'OF INITIAL SYSTEM: PRESSURE DISTRIBUTION <br /> <br />MINIMUM SEPTIC TANK CAPACITY: <br />LIHEAL FEET OF DRAINFIELD: <br />TYPE OF DISTRIBUTIONI <br /> DISPOSAL TRENCH DEPTH: <br /> TOTAL DRAIN MEDIA DEPTH: <br /> DRAIN HEDIA UNDER PIPE~ <br /> MINIMUM SOIL BACKFILL: <br /> GROUND WATER INTERCEPTOR~ <br /> <br />1~00 GALLONS <br /> 225 <br />EQUAL <br /> 18INCHES, MINIMUMl 24INCHES, MAXIMUM <br /> 12INCHES <br /> 6INCHES <br /> 6INCHES <br /> N <br /> <br /> The disposal trenches are constructed two (2) feet wide and on minimum ten (10) foot centers <br /> and with no lithe exceeding 125 feet in length. The trenches and perforated pipe are <br /> installed level (+/- one inch) and contoured to follow the natural ground surface. <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM~ PRESSURE DISTRIBUTION <br /> <br />COHMENTS AND CONDITIONS <br /> <br />1. THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON MAY 28 <br /> 1997. INSTALL AS PER REVISED PRESSURIZED DISTRIBUTION PLANS <br /> DATED HAY 28. 1997. OBSERVE ALL USUAL SETBACK AND SEPARATION <br /> DISTANCES. USE CARE HOT TO ALTER THE NATURAL TOPSOIL WITHIN <br /> THE DRAINFIELD SITES PRIOR TO INSTALLATION. <br />2. The attached ORANGE CARD Rust be posted at the county road. <br />3. The site must be protected from traffic, livestock, Yarming <br /> or other damaging activities. <br />4. This system must be inspected prior to cover.- When work is <br /> complete, call our Automated Inspection Request Line, <br /> at373-4427, to request an "881" PRE-COVER inspection. <br /> ~pavea.nessage (or.the inspector to indicate ~he name of. <br /> :ne inszaller aha pnone nueoer, the size of tank installea <br /> and the length of drainfield. An inspection should be <br /> completed within seven (7) days. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.