Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 ° Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 ° Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />DATE/TTHE <br />TYPE <br />CL~SS <br />OCCUPAI'E'.Y <br />COHgTRUCT'[OI,! <br /> <br /> BLIIL])INC PERHTT <br />.' Connercia! additJon/a]teration <br /> <br />: S-5 <br />: V-N <br /> <br />PERHIT NO : 96-~8714 <br />STATUS :[SSUF. I) <br />ISSUED : ~3/~3/1997 <br />TO EXPZRE = B8/3~/~977 <br />PACE 2 <br /> <br />PI.AN REVIEW COMMENTS AND CONDITIONS <br /> <br />RFBUIRFP SFTRACKS= Front: Left:= <br /> OK AS PER SITE PI. AN <br /> <br />Right: Rear: <br /> <br />Special: <br /> <br />]. TNIS PLAN RFVIF'W WAS COHPLETF~ BY J TRLISSELL ON 2-27-97. <br />~. Approval. of submitted plans is not an approval of OMissions <br /> or oversights b~ this office or of nonceMpliance with any <br /> app'Li,':ahl~ regulations of 'Local government. <br />3. Approved address numbers sha~l bP painted or affixed to the <br /> front of the building in a contrasting and highly visible <br /> cn]or~ not ]es~ tb~n six (~) inches in height for <br /> COMMercial use or four (4) inches in height for residential <br /> u~e. The nuMber~ sha]] be affixed prior ~o final <br /> inspection. (5l~) (OPC 1~.~81) (ORD 774) <br />4. A roadside Marker shall be placed at the access point with <br /> address numbers in a contrasting and highly visible color~ <br /> not less than five (5) inches in height' for COMMercial use, <br /> or three (~) inches in height for residential use. <br />5. TI'm INSPECTION RFCORP GREFN CARD shall be posted in a <br /> visible and readily accessible location throughout <br /> construction. <br /> APPROYE;) CONSTRUCTION PLANS AND PLAN REVIEW COMMENTS AND <br /> CflNPITIONS shall be kept on the site of the building or work <br /> at the time of inspection. <br />6. Work May proceed only at' the direction of the inspector. <br /> To request a~ inspection of completed work, DIAL <br /> (503) 373-4427 (24-hour inspection line) prior to 7:00 A~ to <br /> rer:~ive same day serv:L~e. <br />7, nSF INSPFCTIOfl gOOFS NNFN RFaIIESTIN~ INSPECTIONS= <br /> 102 - FOOTINGS. stake property lines and call before pour <br /> ~03 LINDFRFLOOR/POST & RFAH <br /> L04 - FRAMING~ call when ~eather ti§ht~ chimney/fireplace <br /> installed, ail backing, fire blocking, stair'% <br /> soffits in place~ pluM~ing, ~lectrical, Mechanical <br /> coMp]ete~ truss detai]s posted~ flood elevation <br /> c~rttifiqation submitted. <br /> ~5 - INSUtATION~ call before covered <br /> I16 9RYWALL '- ca'L1 before taped <br /> ~87 POIF NO[FS, cal~ before pour <br />8. 1~8 FOUNDATION WALl. REBAR <br /> 1~0 - MASONRY RFRAR <br /> 111 - SPECIAL BRACE PANEI.S <br /> 1~2 - MASONRY FIRFPLACF PRF-COYFR <br /> ll~ - SUSPENOEO CEII.[NG <br /> 1~4 - ROOF NAILING <br /> 115 - ~EMOLITION INSPECTION <br /> Il& - OTHER STROCTURAi INSPECTION <br /> 177 - STROCTHRAL FINAl_ <br />?. FOR FIRF SPRINKLER SYSTEMS: 504 -- Ft. OW TEST <br /> 5~5 -FIRF A[ARN TFST <br /> 506 - TRIP TEST <br /> 507 - FLUSHING <br /> 5~8 - COMNMERCIAL NO00 SIIPPRESSION SYSTEM <br /> 509 - SPRINKI ER SYSTFM/OVFRHEA~ <br /> 510 - SPRINKI.ER SYSTEN/UNOERGROllND <br /> 577 -FIRF SPRINKI FR FINAl. <br /> Exit doors shall be openat)l~? from th~ inside without the <br /> use of a key or any spPria~ knowledge or effort. Manually <br /> operat~(I adga or surfaco bolts are prohibited. <br /> A water supply suffir:ient to control a potential fire is <br /> required. Sam Appendix II[-A ~f t:ha JniforM Fire Code. <br /> <br /> <br />