My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1466492
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
96-XXXXX
>
BUILD - 1466492
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2013 2:04:02 PM
Creation date
8/9/2004 2:21:09 PM
Metadata
Fields
Template:
Permits
Permit Address
13740 CEDAR CT NE
Permit City
Aurora
Permit Number
555-96-07787
Parcel Number
041W11CB02500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MARION COUNl BUILDING INSPECTION <br /> COMMUNll~f DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Houre: 8:00.4:30 · Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />~ATE/TJIE <br />TYPIC <br /> <br />OCCUPAHCY <br />CO~TRtlCT)'ON <br /> <br /> BIJILD[N[; PERHZT <br /> : 19/16/96 16s97 PERflZT 140 : 96-~7787 <br />: Resident. addition/alteration STATUS t [SSUED <br />; b]lJng addition/alteratton ZgSUED : 18/16/1996 <br />~ u-~ To £X~;R£ ~ 04/14/1997 <br />s V~ PN;£ 3 <br />~hall he required on each side of an egress door. The floor <br />or landing sha]l not' be more than ~ an~ 1/2 inches lower <br />than the ~op of the threshold. Exception= The landing at <br />the exterior doorway :hal] not be More than 8 I/4 inches <br />below the top of the threshold. ESot. 312.1] <br />~TA)RWAYS sha]) not be les~ than 36 inches in clear width at <br />all points between the handrail height and the reRuired <br />MiniMUM headroom of 6 feet 8 inches. NiniMuM width from the <br />handrail down is 32 inches with one handrail, 28 inches with <br />two. The MiniMuM required stair tread width is ~ inches. <br />The MaxiMuM stair rise is 8 inches. When risers are closed~ <br />a]] ~reads le~s than 1~ inches shall have a uniform nosing <br />betweeM 3/4 inches and 1 1/4 inches. The greatest riser <br />height/tread depth sha!l not ~xced th ~Mallest by More than <br />3/8 inch. ~Sec. 314.1~ ~14.2~ ~14.2.1~ 314.33 <br />ALL EXTERIOR STAIRS shall be provided with a MiniMuM of 60 <br />~atts of incandescent light or other artificial light source <br />rated at a MiniMUM of 858 lumens. The illumination of <br />exterior stairs shall be.located in the iMMediate vicinity <br />of the landing at the top of the stairs of resulted exits, <br />and shall be controlled from inside the dwelling unit unless <br />continuously i]]uM~nated or automatically activated. <br />Exception: An artificial light source is not required at <br />the top and bottom of stairs provided the artificial light <br />source is located directly over each stair section. <br /> <br />GI.IAR~RAIL OH STAIRS. i]pen sides of stairs with a total rise <br />or More than 38 inches above the floor or grade below shall <br />have guardrails not less than 34 inches in height Measured <br />vertically from the nosing of the treads. Guardrail shall <br />have intermediate rails or ornamental closures which will' <br />not allow passage of an object 6 inches or More in diameter. <br />Horizontal spacing between the vertical MeMbers in required <br />guardraiIs shall §e a MaxiMuM of 4 inches at the nearest <br />noint between the MeMbers. [Sec. 315.3, 315.4] <br />~NIIKE' ~FTEC~ORS / Ai'TE~ATIONS. When alterations, repairs or <br />additions are Made to an existing dwelling, the entire <br />hut]ding shad] be provided with smoke detectors located as <br />required for new dwellings. The smoke detectors are not <br />toque, red to be interconnected unless other remodeling con- <br />sid~rations require removal of the appropriate wall and <br />ceiJing coverings to facilitate interconnecting wiring. <br />[Sac in 31 1.1] <br /> sha l be installed in each sleepi.g rooM, <br />outside of each separate sleeping area in the iaMediate <br />vicinity of the bedrooms and on each additional story of the <br />dwelling including basements. All detectors shall be inter- <br />connected such that the actuation of one alarm wil! actuate <br />all the alarms in the individual unit and shall provide an <br />a)ara which wi1] be audible in a)] s]eepinq areas. <br />CSection 316.13 Smoke detectors shall be IlS volt with <br />battery back-up, ESot. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.