My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1465094
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
97-XXXXX
>
BUILD - 1465094
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2013 10:15:11 AM
Creation date
8/9/2004 1:29:59 PM
Metadata
Fields
Template:
Permits
Permit Address
8881 LITTLE RD SE
Permit City
Aumsville
Permit Number
555-97-01717
Parcel Number
082W36C 02500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon 97305-1398 <br />Office Houm: 8:00-4:30 ° Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />DATE/T[HE <br />TYPE <br />CLASS <br />OCCUPANCY <br />COHSTRUCTTOH <br /> <br /> BUILDING PERHIT <br />: O&/SA/97 11:13 <br />: Resident. addition/alteration <br />: D~elling addition/alteration <br />: R-3 <br />: v-g <br /> <br />PERflIT HO : 97-81717 <br />STATUS : ISSUED <br />ISSUF_~ : ~6/86/1997 <br />TO EXPIRE : 12/~/1997 <br />PAGE 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 I.eft: 20 Right: 20 Rear: 28 Special: <br /> <br /> 1. THIS PLAN REVIEW WAS COMPLETED BY J TRUSSELL ON 6-5-97. <br /> 2. Approval of submitted plans is not an approval of OMissions <br /> or oversights b~. this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 3. Approved address numbers shall be painted or affixed to the <br /> front of the building in a contrasting and highly visible <br /> color, not less than six (6) inches in height for <br /> COMMercial use or four (4) inches in heiqht for residential <br /> use. The numbers shall be affixed prior ~o final <br /> inspection. (513) (UFC 10.~01) (OR]) 774) <br /> 4. A roadside Marker shall be placed at the access point with <br /> address numbers in a contrasting and highly visible color, <br /> not less than five (5) inches in height for COMMercial use, <br /> or three (3) inches in height ~or residential use. <br /> 5. The INSPECTION RECORD GREER CARD shall be posted in a <br /> visible and readily accessible location throughout <br /> construction. <br /> APPROVED CONSTRUCI'ION PLANS AND PLAN REVIEW COMMENTS AND <br /> CONDITIONS shall be kept on the site of the buildin~ or work <br /> at the time of inspection. <br /> 6. Work May proceed only at the direction of the inspector. <br /> To request an inspection of Completed work, DIAL <br /> (50~! ~7~-4427 (24-hour inspection line) prior to 7:88 AM to <br /> receive same day service. <br /> 7. USE INSPECTION CODES WHEN REQUESTING INSPECTIONS: <br /> 182 - FOOTINGS, stake property lines and call before pour <br /> 10~ UNDERFLOOR/POST & BEAM <br /> 104 - FRAMING, call when weather tight, chimney/fireplace <br /> installed, ali. backing, fire 6locking, stairs, <br /> soffits in place, plumbing, electrical, Mechanical <br /> coMplete~ truss details posted, flood elevation <br /> certtification submitted. <br /> 105 - INSULATION, call before covered <br /> 186 - DRYWALL - call bernie taped <br /> 187 POLE HOLES, call beTore pour <br /> 8. 1~8 FOUNDATION WALL REBAR <br /> 110 - MASONRY REBAR <br /> 111 - SPECIAL BRACE PANELS <br /> 112 - MASONRY FIREPLACE PRE-COVER <br /> 113 - SUSPENDED CEILING <br /> 114 - ROOF NAILING <br /> 115 - DEMOLITION INSPECTION <br /> 116 - OTHER STRUCTURAL INSPECTION <br /> 1~ - STRUCTURAL FINAL <br /> ?. FOR FIRE SPRINKLER SYSTEMS: 584 - FLOW TEST <br /> 585 - FIRE ALARM TEST <br /> 506 - TRIP TEST <br /> 587 - FLUSHING <br /> 508 - COMNMERCIAL HOOD SHPPRESSION SYSTEM <br /> 509 - SPRINKLER SYSTEM/OVERHEAD <br /> 510 - SPRINKL ~R SYSTEM/UNDERGROUND <br /> 59~ - FIRE SPRINKLER FINAL <br />~0. GROUNDING EL..CTRODES. When concrete reinforcing bars are <br /> installed in concrete footings, the following requirements <br /> shall he met to grovide for a urounding electrode system <br /> 1. Uncoated No. ~ reinforcing 5ar installed not less <br /> .-0 feet in length encased with a Minimum of 2 inches of <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.