My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SESPNEW - 1456156
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
96-XXXXX
>
SESPNEW - 1456156
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2010 11:30:11 AM
Creation date
7/21/2004 11:16:47 AM
Metadata
Fields
Template:
Permits
Permit Address
6605 HAYS LN SE
Permit City
Aumsville
Permit Number
555-96-06249
Parcel Number
081W19C 00600
Permit Type
SESPNEW
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
April 26, 1994 <br /> <br />APPLICANT: <br />SITE NUMBER: <br /> <br />STANDARD SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />ARNOLD ADKINS <br />94-1466 <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br />1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />450 aallons Der day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 150 lineal feet Der 150 <br />qallons of projected daily sewage flow. A minimum of 450 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with serial distribution <br />with a minimum trench depth of 24 inches and a maximum trench <br />depth of 24 inches. There must be at least 12 inches of backfill <br />over the top of the gravel, measured from the natural ground <br />surface. <br /> <br /> A groundwater interceptor is required as part of this system. This <br />interceptor trench must be constructed a minimum twelve (12) inches wide by 42 <br />inches deep with 36 inches of clean gravel placed over a four (4) inch smooth <br />wall perforated pipe. The interceptor must be located at least ten (10) feet <br />upslope from the disposal field and must discharge through a watertight, non- <br />perforated pipe beside or below the disposal field. A separation of 25 feet is <br />required from the septic tank if the tank is located upslope of the groundwa- <br />ter interceptor. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS: <br /> The drainfields must be installed within the immediate area of the two <br /> easterly soil test pits and no farther downslope. Note, that the <br /> westerly test pit is dug beyond the property line. A pre-construction <br /> field stakeout is recommended to establish the locations and elevations <br /> of the individual drainfield lines for both systems prior to siting any <br /> wells and any excavation. Refer to the enclosed stakeout procedure and <br /> the setback list for details to complete the stakeout. Note, especially <br /> the required separation distance between the septic tank and curtain <br /> drain depending upon whether the tank is above or below the curtain <br /> drain. Soil conditions are marginal so use care not to alter the natural <br /> topsoil prior to drainfield construction. <br /> <br />TillS IS NOT A PERMIT TO INSTALL THE SEPTIC SYSTEM. DO NOT INS~aT3. THE SYSq~ <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY THIS OFFICE, <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.