Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 * 24-HR Inspection Line: (503) 373-4427 <br /> <br />D~TE/TIHE <br />TYPE <br />CLASS <br />OCCUPANCY <br />COI~ITRUCTTON <br /> <br /> BUILDIHG PERRIT <br /> : 88/26/96 17105 PERHIT HO z 96-05819 <br /> : Res/dent. addition/alteration STATUS ; ISSUE~ <br /> : D~e]ling addition/alteration ISSlJED = S8/26/1996 <br /> : R-3 TO EXPIRE : ~2/22/1997 <br /> : V-N P~GE 3 <br /> not specifically detailed in the subeitted plans and struc- <br /> tural calculations is beyond the scope of this review, <br />11. TRUSS DESigN. Roof trusses are re~uire~ to be be designed by <br /> an Oregon registered Engineer or architect, For trusses <br /> nanufactured by an approved fabrication plant~ have the <br /> design and layout dra~ings available at the construction <br /> site for the fra~ing inspectiun. All jobsite cutting or <br /> codifications of the roof trusses shall be clearly s~own in <br /> the engineer's ~esign calculations an~ drawings. This ~ould <br /> be applicable ~? on*y~ lets say 1/2 o~ a truss oas being re- <br /> ,oved~ then the remainder,of t~e truss, would have to be <br /> checked by the truss ~anu~acture to de,steins that it <br /> structurally support any loads that tt nay have to carry. <br />17, ATTIC VENTS. Provide screened attic ven~s ~ith a net free <br /> area of 1/1~ of the attic area (or 1/388 if between 58 of <br /> Sg percent of reguired area is ~entilators in the upper <br /> portion of the attic and locates at least 3 feet above save <br /> or cornice vents). As an a]ternative~ install a 1 ~il vapor <br /> barrier on the ware side of tt!e ceiling. [Sec. 886.23 <br />]3. HANDRAILS having a ainieua and aaxznum height of 38 inches <br /> and 38 inches, respectively~ ~hall he prowded on at least <br /> one side of s~airways of more than three risers, All re- <br /> quired handrails shall be continuous the full length of the <br /> stairs. End~ shall be returned or shall laminate in newel <br /> sis or safety terminals. Exceptinn~ Handrails nay be <br /> nterrupted by a ne~e]r post at a turns and the use of a <br /> volute turnout or starting easing shall be allowed over the <br /> lo,est tread, CSec, <br />~4. THE HANDGRIP PORTIfiN of ~andrails ~hall not be Zess than <br /> ~ ~/4 inches or sore than 2 5/8 inches in cross-sectional <br /> di~ension~ or the shape ~hall provide an equivalent gripping <br /> surface. T~e handgr~p portion sh~ll have a snoo~h surface <br /> and edges snell have a ~ininu~ raeius of 1/8 inch. <br /> ESection 315.1] <br />15. SMOKE DETECTORS ! ALTERATIONS. When aiterations~ repairs or <br /> additions are ~ade to an existing dwelling~ the entire <br /> buildinq shall he provided with s~oke detectors located as <br /> require~ for ne~ d~el]ings. The s~oke detectors are not <br /> required to be interconnected unless other remodeling con- <br /> siderations require removal of the appropriate wall and <br /> ceiling coverings to facilitate interconnecting wiring. <br /> [Seczion 316.1.I3 <br /> l&. SMOKE DETECTORS [SPLIT LEVEL] shall be installed in each <br /> sleeping roo~ outside of each separate sleeping area in the <br /> i~ediate vicinity of the bedrooms and on each additional <br /> story of the d~e]ling including base,sots. A smoke detector <br /> need he installed unix on the upper ievel~ provided the <br /> lower level is less than one full story belo~ the upper <br /> level, except that if there is a door between levels, a de- <br /> tector is required on each level. All detectors shall be in- <br /> terconnected such that the actuation of one alar~ will actu- <br /> ate all the alarms in the individual unit and shall provide <br /> an alar~ which ~ill be aud~bl~.in, all yleFpino ares. S~oke <br /> detectors shall be 118 vol~ w/gallery oac~up [Sec 31&.l~ 2] <br /> 17. SMOKE DETECTOR / POWER. Required s,o~e detectors shal.1 <br /> receive their primary ~ower ~ro~ the uuilding ~iring when <br /> such wiring is served fro~ a co,~ercial source~ and ~hen <br /> ~ri~ary po~er is interrupted~ shall receive power fro~ a <br /> artery. S~oke detectors ,ay be battery operated ~hen <br /> ~nsta]led in buildings w~thout co,~ercial power. ESec. 316.2] <br /> lB. FIRESTOPPtNG shall be provided in the following locations. <br /> 1. In concealed spaces of stud wal]s~ including furred <br /> spaces not to exceed 1~ feet hori~.rmtaliy~ ~nd at the <br /> ce~lJng and floor level. <br /> At all intercun~mctirms between* concealed ve*tical a~d h <br /> horizontal spaces such as occur at soffits, dro~ or cove <br /> <br /> <br />