My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
MANF - 1454827
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
96-XXXXX
>
MANF - 1454827
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2010 10:51:32 AM
Creation date
7/21/2004 10:59:10 AM
Metadata
Fields
Template:
Permits
Permit Address
925 YORK ST
Permit City
AUMSVILLE
Permit Number
555-96-04805
Parcel Number
081W30 02300
Permit Type
MANF
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MARION COUNI BUILDING INSPECTION <br />COMMUNll DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 * Phone: (503) 588.5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />D~TE/T~#E <br /> <br /> ltiINUFACTU~ED OMELLINI; PERHIT <br /> = 07/08/96 96:37 PER~ZT NO = 96-84885 <br /> = He~ Manufactured D~elling 5TRTUS = ISSUED <br /> = R-3 ISSUED = S7/B8/1~96 <br /> TO EXP[RE ~ B1/~4/1997 <br /> P~GE 3 <br /> Manufactured dwelling read% fo? occupancy. Assigned street numbers shall be <br /> painted or affixed to the front of the dwelling in a contrasting and highly <br /> visible color~ not less than four (4) inches in height. <br /> <br /> Th~s inspection includes checking construction and code requirements for decks <br /> and steps~ skirting and underfloor ventilation and access. <br /> <br />A RF~NSPECTION FEE OF $60.00 shall be assessed for each inspection beyond the <br />permitted thr~e inspections or (1) when the permit card is not posted <br />on the job site; (2) for failure to provide access on the date for which <br />the inspection is requested; (3) when the work for which an inspection is <br />requested is not complete, [4) when the Manufactured dwelling is not installed <br />per 199& Manufactured Dwelling Standards; (5) for failing to attach an installer's <br />certification tag, or (6) when required corrections are not Made. No inspections <br />will be perforned until the reinspection fee has been paid at our office. <br /> <br /> OTHER COMMENTS AND CONDITIONS <br /> <br /> 1. THY5 PLAN REVIEW WAS COMPLETED BY S. FREILINGER ON 7/1/76. <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local ~overnMent. <br /> 3. A roadside Marker shall be placed at the access point with <br /> address numbers in a contrasting and highly visible color~ <br /> not less than three (3) inches in heighf. <br /> 4. Site grading and drainage shall @rovide grades which slope <br /> downward away from Manufactured Uwelling stands, foundation <br /> food:logs, concrete slabs, patios~ wal]% skir~ing, and. <br /> founds:ions at a MINIMUM GRA~E OF 1/2 I~CH PER FOOT FOR 6 <br /> FE~¥ horizontally. (Sectioo ~02(c) 1~6 Oregon Manufactured <br /> ~w~ ~Iing Code Standards). <br /> 5. Provide at least I square foot of underfloor ventilation <br /> for each 158 square feet of crawl space area. The openings <br /> shall be covered with a corrosion resistant wire Mesh. At <br /> least one such opening shall be provided within ~ feet of <br /> each corner of the building. (R-~11.1) <br /> 6. Provide an access crawl hole to the underfloor space. The <br /> MiniMuM size opening required is 18 inches by 24 inches. <br /> <br /> 7. ~ai~waXs shal~ not b? less than ~ feet in clear width and <br /> toe neaorooM shall not be less than 6 feet 8 inches. The <br /> MiniMuM r~quired stair_trea~ width is ~ inches. The <br /> MaxiMuM stair rise is ~ inches. When risers are <br /> closed, all treads May have a uniform projection not to <br /> exceed i and 1/2 inches. The greatest riser height shall <br /> not exceed the smallest by More than ~/8 inch. (R-213.1) <br /> 8. Handrails Meeting the following reguireeents shall be <br /> proyided gn at least one side ~f stairways. The handgrip <br /> por:~on OT handrails shall be not More than 2 5/8 inches in <br /> cross-sectional dimension, or the shape shall provide an <br /> equivalent gripping surface. Handrails shall be Mounted <br /> between a MiniMuM of ~0 inches and a MaxiMuM of ~S inches. <br /> They shall be continuous the full length of the stairs. <br /> Ends shall be returned or shall terminate in newel posts or <br /> safety terminals. <br /> (R-214.1) <br /> 9. A MiniMuM ~' X ~' landing shall be required on each side of <br /> an egress door. The floor or landinq shall not be More <br /> than'one and one-half inches lower t~an the top of the <br /> threshold. (R-212) Exce@tion: The l~nding on the <br /> exterior side of an exterior doorway shall not be More than <br /> ~ an~ 1/4. iDche5 below the top of the ~hreshold... <br /> 10. rorcnes~ oalconzes or raised ¥1oor surTaces iocaten More <br /> than~30 i~. ahoye thp floor, o~ g~ad~ shall.have gua~ra~l <br /> no~ J~ss than ~ inches in heighT. ~equlrec guaroraii snail <br /> have intermediate rails or ornamental closures which will <br /> <br /> <br />