Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br />DAT[/TIHE <br />TYPE <br />OCCUPANCY <br /> <br /> 285 Church Street NE * Room 132 * Salem, Oregon 97301-3670 <br /> Office Hours: 8:00-4:30 · Phone: (503) 588-5147 * 24-MR Inspection Line: (503) 373-4427 <br /> <br /> SITE EVAI.UATTDN APPROVAL <br />: B7/15/96 18:e2 APPROVAL NO ~ 96-84312 <br />: SE s'rATb~ : APPROVED <br />.' R-3 APPROVED ~, 87/15/1996 <br /> <br />PAGE 2 <br /> <br /> SITE EVALUATION APPROVAL <br /> <br />This property has been evaluated for the feasibility of the installation of a septic <br />systen for a RESIDENTIAL building site. Based on the results of this study, size evaluation <br />a~pr°val is qranted. The approval is site specific to the area tested, and the ~eptic sy=~eM <br />Must be located in the iMMediate area of the test pits, unless otherwise authorized by this <br />office. A new site evaluation May be required if the system is proposed for a different <br />area on the property. <br /> <br />This approval is given on the basis that the lot or parcel will not be further partitioned <br />Or subdivided and that conditions on this property and on adjacent properties are not altered in, <br />amy Manner which would prohibit the issuance of a permit. Soils in the approved area shall not ne <br />altered or Modified by cutting, filling, or other developmental activities which would impede the <br />successful operation of the initial or replacement soil absorption systems. Failure to comply with <br />th~ above items May void this approval. <br /> <br />This report is not a permit toinstall the sewage systeM. A permit Must be obtained before <br /> <br />· p ..Die wi~n applicable LCDC acknowledged local comprehensive land use pla~. A Stat~..Ment of <br />Land Use CoMpatibility or its equivalent is required before a construction perMit ca~ be issued. <br /> <br />A detailed site plan. drawn to scale (ex: 1" = 68")~ Must be submitted with the permit <br />application before t~e construction-installation permit can be issued. The system Must be <br />installed by the property owner or a registered contractor. <br /> <br />This site evaluatioM report is valid until an on-site sewage system is installed pursuant to the <br />Eonstruction permit obtained from this office, or until cancelation pursuant to the E~vironMent~l <br />uuality COMMission Rules. Subject to the above, this report runs with the land and will autoMat- <br />ically benefit subsequent owners. <br /> <br />Site conditions will require the following installation specifications: <br /> <br />TYPE OF INITIAL SYSTEM: <br /> <br />STANgARB <br /> <br />MINIMUM SEPTIC TANK CAPACITY: 1888 GALLONS <br />LINEAL FEET OF DRAINFIELD: 458 <br />TYPE OF DISTRIBUTION: SERIAL <br />DISPOSAL TRENCH DEPTH: 24INCHES, MINIMUM; 24INCHES, MAXIMUM <br />TOTAL DRAIN MEDIA DEPTH: 12 <br />DRAIN MEDIA UNDER PIPE: 6 <br />MINIMUM SOIL BACKFILL: 12 <br />GROUND WATER INTERCEPTOR: Y <br /> <br /> TYPE OF FUTURE REPLACEMENT SYSTEM: STANDARD <br /> <br />Before any installation takes place, a perMit Must first be obtained from Marion County. <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1. THIS SEFTIC REVIEW WAS COMPLETED BY ,LEE GRIMES ON JULY 11, <br /> !996. INSTALl.. THE DRAINFIEL. I)S AS FAR UP-SLOPE AS POSSIBLE. <br /> RE. ,ER TO SITE PLAN DA~.ED JULY 12, 1996. NOTE, THE UP-SLOPE <br /> £.UR[AIN I)RAtN~ iSE CARE NOT TO ALTER THL:: NATURAL. TOPSOIL <br /> WITHIN THE DRAIFIEL. D SITES F'R:[OR TO INSTALLATIOI,I. A PRE- <br /> CONSTRUCTION FIELD STAKEOUT IS RECOMMENDED TO CONFIRM I'HE <br /> E.~..:~A,ION. AND LOCATIONS OF THE INDIVIDUAL DRAINFIELD LIN~=S. <br /> RFFER TO THE S'~AiEf) I'F PROCEI) IR~ AND THE SETBACK LIST FOR <br /> Dk:TATL. S TO OOMFLE'FE-I'HE ST~KEOdT. THERE IS A MODERATE TO <br /> <br /> <br />