Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours 8:00-4:30 · Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br /> SEPTIC PERMIT <br />lATE/TINE ~ ~7/1~/96 I§~24 PERHIT NO = 96-B4187 <br />TYPE = ~P STATUS = ISSUED <br />OC?-J&PANCY : R-3 ISSUED = ~7/~1/1996 <br /> TO EXPIRE ~ e7/~1/1997 <br /> <br /> SEPTIC PERMIT <br /> <br />This property was prev,i, ous~ly eva]luated 04/15/1992 ~or the feasibJ, lity t'o install @ <br />septic System for a RESIDENTIAL bu~.ldinp site. B,~ed on the results of this study~ site <br />approval was granted. The approval is site specific to the area tested~ and the s~ptic <br />System must be located in the immediate area of the test pits, unless otherwise autho¥i~ed <br />b~ this office. A new sit~ evaluation May be required if the system is proposed for a <br />dsfferent area on the property. <br />This approval was ~iven o~ the basis that the lot or parcel will not be fu¥'ther par~itioned <br />or subOsvided amd ~hat conditions on this property and on adjacent properties are not altered <br />in any manner which would prohibit the issuance of a permit. Soils in the approved area <br />shall not be altered by cutting, fiIling, or' other developmental activities which would <br />impede the successful operation of the snitial or replacement absorptio~ systems. Failure <br /> comply with the above items may void this approvaz. <br /> <br />The site evaluation approval runs with the ].and, but the permit is non-transferable a¥~d non- <br /> <br />Keep this document with yo~r records. Show this permit to the septic i~staller prior 'to <br />installation of the system. Any deviation fl"om the approved plan must have prior app,'oval from <br />this office. <br /> <br />The following construction specifications shall apply to the installation of the initial <br />~eptic system: <br /> <br />TYPE OF' INITIAL. SYSTEM: PRESSURE DISTRIBUTION <br /> <br /> MINIMUM SEPTIC T_AHK CAPACITY: 1880 GALLONS <br /> LINEAL FEET OF! DRAINFIELD: 225 <br /> TYPE OF ~ISTRIBUTION: LOOP <br /> DISPOSAL TRENCH DEPTH: 12INCHES, MINIMUM; 12INCHES~ MAXIMUM <br /> TOTAL DRAIN ~EDIA DEPTH: 12INCHES <br /> DRAIN MEDIAi UNDER PIPE: 6INCHES <br /> MINIMUM SGIL BACKFILL: 16INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br /> The disposal trenches are constructed two (2) feet wide and on Minimum ten (10) Foot centers <br /> and with ~o line exceeding 125 feet in length. The trenches and perforated pipe are <br /> installed level (+/- one Inch) and contoured to follow the natural ground surface. <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM: PRESSURE DISTRIBUTION <br /> <br />COMMENTS AND CONDITIONS <br /> <br /> S E W ET Y L R M S ON ULY 11 <br /> <br /> OF THE EASTERLY TEST PIT. OBSERVE ALL USUAL SETBACK AND SEP- <br /> ARATION DISTANCES. NOTE. THE SHALLOW DEPTH OF THE DRAINLINE <br /> TRENCHES AND THE CAPPING FILl. REQUIREMENT. AN EFFLUENT PUMP <br /> WILL BE NECESSARY TO PRESSURIZE THE DISTRIBUTION NETWORK. <br /> REFER TO SITE PLAN DATED JUL. Y 11,. 17~6. DRY SOIL SUMMER SEA- <br /> SON CONSTRUCTION IS REQUIRED TO FLACE THE CAPPING FILL. THE <br /> FILL MATERIAL MUST BE APPROVED PRIOR TO PLACEMENT. <br />2. The attached ORANGE CAR~ Must be posted at the county road. <br />~. The site Must be protected from traffic, lives~ock~ farming <br /> or other damaging activities. <br />4. This syst~ must be inspected prior to cover. To request <br /> an u.)'Ispec~.om or completed work, ~::~13 588-7~04 (24-hour <br /> li~e). When requesting the inspection, be sure to give <br /> <br /> <br />