Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> ~85 Ohuroh Street NE · Room 18~ · 8ilem, Oregon <br />C)ffloe Hour.: 8:00-4:~0 * Phone: (808) M~147 · 14-HR Inspeotion Line: (~0,1) 87~.4427 <br /> <br /> HAJOR SEPTIC REPAIR PERHIT <br />DATE/TIHE : B5/24/96 14:5! PERHIT HO : 96-83872 <br />TYPE : SP STATUS : ISSUED <br />OCCUPANCY : R-3 ISSUED : 85/24/1996 <br /> TO EXPIRE : 85/24/~997 <br /> PAGE 2 <br /> <br /> MAJOR SEPTIC REPAIR PERMIT <br /> <br />Th~s property has been evaluated for a septic system repair permit for feasibility to repair <br />an existing septic system for a RESIDENTIAL building. Based on the results of this study. <br />site approval has been granted. This approval ~s specific to the area tested, and the syste~ <br />must be installed in the immediate area of the ~est pits. <br /> <br />Soils in the approved area shall not be altered or modified by cutting, filling, or other <br />activities which would impede the successful operation of the septic ~ystem. Observe all <br />r~quired setback/separation distances during the inst~llation of the system. <br />Keep this document with your records. Give a copy of this permit to the septic system <br />instal]er prior to the installation of the system. Any deviation from the approved plan <br />~ust have prior approval from this office. <br />The follow~nQ construction specifications shall apply to the installation of the septic system: <br /> TYPE OF REPLACEMENT SYSTEM: STANDARD <br /> <br /> MINIMUM SEPTIC TANK CAPACITY: 1888 GALLONS <br /> LINEAL FEET OF DRAINFIELD: 225 <br /> TYPE OF DISTRIBUTION: EQUAL. <br /> DISPOSAL TRENCH DEPTH: 18INCHES, MININUM; 24INCHES, MAXIMUM <br /> TOTAL DRAIN MEDIA DEPTH: 12INCHES <br /> DRAIN MEDIA UNDER PIPE: 6INCHES <br /> MINIMUM SOIL BACKFILL: 6INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br /> The disposal trenches are constructed two (2) feet wide and on minimum ten (18) foot <br /> centers and with no line exceeding 125 feet in ~engt~. The trenches and perforated <br /> p~pe are installed level (+/- o~e'inch) and con~oure0 to follow the natural ground <br /> surface. <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1. THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON MAY 7, <br /> 1996. INSTALL THE DRAINFIELD WITHIN THE IMMEDIATE AREA OF <br /> THE TEST PI1S. AVOID CONCAVE LANDFORMS. THE EXISTING SEPTIC <br /> TANK MUST BE PUMPED AND PROPERLY ABANDONED. USE CARE NOT TO <br /> ALTER THE NATURAL TOPSOIL WITHIN THE DRAINFIELD SITES PRIOR <br /> TO ~NSTALLATION. MAINTAIN AL[. USUAL SETBACK AND SEPATATION <br /> DISTANCES. <br />2. [he attached ORANGE CARD must be posted at the count% road. <br />~. The site must be protected from traffic, livestock, far'ming <br /> or other damaging aqtivities. <br />4. This system must be inspected prior to cover. To request <br /> an inspection of ~ompleted work, call 588-/?84 (24-hour <br /> line). When requesting the inspection, be sure to give <br /> installer s naMe~ phone nuMb.r~ si~e of tank, and total <br /> length of drainfzeld. Inspectzon will be completed within <br /> seven days of request. <br /> <br /> <br />