Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 ° Phone: (503) 588-5147 · 24-HR InepeclJon Line: (503) 588-7904 <br /> <br />DATE/TZHE <br />TYPE <br /> <br /> HA~UFACTURED DWELLZNg PER~IT <br /> = ~3/~4/96 13=56 PERHIT HO = 96-~1147 <br /> = He# Hanufactured,D~elling STATU~ = ISSUF. J) <br /> = R-3 ISSUED ~3/~4/1996 <br /> TO EXPIRE ~ ~8/31/1996 <br /> manufactured dwelling readx for occupancy. Assi§ned street numbers shall be <br /> painted or. affixed to the front of the dwelling in a contrasting and highly <br /> visible co~or~ not less than four (4) inches in height. <br /> This inspection includes checking construction and code requirementsr for decks <br /> and steps~ skirting and underfloor ventilation and access. <br />~.REIHSPECT~OH FEE oF .$~.0~ shall be assessed for each inspection beyond the <br />permitted three inspections or (1) when the permit card is not posted <br />on the ~ob site; (2) for failure to provide access on the date for which <br />the inspection is requested~ (3) when the work for which an inspection is <br />requested is not complete, (4) when the manufufac~ured dwellin~ is not installed <br />per 197~ Hanufactured Dwe/ling Standards~ or (5) when required corrections are <br />not ~ade. Ho inspections wi1! be performed until the reinspection fee has been <br />paid at our off/ce. <br /> <br /> UTHE~ BOHHENT~ ~ND COND~T~ON~ <br /> <br /> 1. THIS PLAH REVIE~ ~S COHPLETED ~Y S. FRE~LINGER OH <br /> 2. Approval of submitted plans is not an approval of <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local <br /> 3. A roadside ~arker shall be place~ at the access point with <br /> address numbers in a contrastin~ and highly visible color~ <br /> not less than three (~) inches in height. . <br /> 4. Wor.k may proceed only at the direction of the inspector. To <br /> re§uest an inspection of completed Work, call 588-7904 <br /> (~4-hour line) prior to 7.00 a.m· to receive same day <br /> service. <br /> 5. Provide at least 1 square foot of underfloor ventilation <br /> for each 150 square feet of crawl space area. The openings <br /> shall be covered with a corrosion resistant wire ~esh. <br /> least one such opening shall be provided within 3 feet of <br /> each corner of the building. (R-311.~) <br /> 6. Provide an access crawl hole to the underfloor space. The <br /> minimum size opening required is 18 inches by 24 inches. <br /> (R-311.2) <br /> 7. ~ minimum 3s x 3~ landing shall be required on each side of <br /> an e§ress door. The floor or la'ndino shall not be more <br /> than one and one-half inches lower tfian the top of the <br /> threshold. (R-212) Exce@tion: The landing on the <br /> exterior side of an exterior doorway shall not be ~ore than <br /> ~ and one-half inches below the top of the threshold. <br /> ~. stairways shall not be les~ than 3 feet itt clear width <br /> the headroo~ shall not be less than 6 feet ~ inches. The <br /> m~nimum required stair tread width is ? inches. The <br /> ~ax~Rm stair rise is 8 1/4 inches, ghen risers are <br /> closed~ all treads may have a unifor~ progection not to <br /> exceed ! and 1/2 inches. The greatest riser height shall <br /> not exceed the s~allest by more than 3/~ inch. (R-213.1) <br /> 9. Handrails.~eeting the following requirements shall be . <br /> provided on at least one side of stairways. The hand,rip <br /> portion of handrails shall be not more than 2 5/8 inches <br /> cross-sectional dimension~ or the shape shall provide an <br /> equivalent gripping surface. Handrails shall be moun~ed <br /> between a minimum of 30 inches and a maximum of 38 inches. <br /> They shall be continuous the full length of the stairs. <br /> Ends shall be returned or shall terminate itt newel posts or <br /> safety terminals. <br /> (R-2~a. 1) <br /> 10. Porchess balconies or rai~ed floor surfaces located more <br /> than 30 in· above the floor or ~rade shall have quardrail <br /> not less than 36 inches in height. Required guar~rail shall <br /> have intermediate rails or ornamental, closures which <br /> not allow passage of an object & in. or more in diameter. <br /> Horizontal spacing between the vertica! members in requii-ed <br /> <br /> <br />