Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00.-4:30 · Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 588-7904 <br /> <br />DATE/TIHE <br />TYPE <br />OCCUPANCY <br /> <br /> H~NUFACTURED D#ELLING PERHIT <br /> : B2/28/96 1B:3B PERHZT NO : 96-~1141 <br /> = Ne~ Hanufactured D.elZing STATUS : ISSUED <br /> = R-3 ISSUED : 82/28/1996 <br /> TO EXPIRE = ~8/26/1996 <br /> PAGE 3 <br /> manufactured dwelling ready for occupancy. Assigned street numbers shall be <br /> painted or affixed to the front of the dwelling in a contrasting and highly <br /> visible color, not less than four (4) inches in height. <br /> <br /> This inspection includes checking construction and code requirements for decks <br /> and steps, skirting and underfloor ventilation and access. <br /> <br />A REINSPECTION FEE OF $60. B0 shall be assessed for each inspection beyond the <br />permitted three inspections or (1) when the permit card is not posted <br />on the job site; (2) for failure to provide access on the date for which <br />the inspection is requested; (3) when the work for which an inspection is . <br />requested is not complete, [4) when the manufufactured dwelling is not installeo <br />per 1796 Manufactured Dwelling Standards, or (5) when required corrections are <br />not made. No inspections will be performed until ~the reinspection fee has been <br />paid at our office. <br /> <br /> OTHER COMMENTS"Ah~) CONDITIONS <br /> 1. THIS PLAN REVIEW WAS COMPLETED BY S. FREILINGER ON 2/27/~6. <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of nonco~pliance with any <br /> applicable regulations of local government. <br /> 3. A roadside marker shall be placed at the access point with <br /> address numbers in a contrasting and highly visible color, <br /> not less than three (3) inches in height. <br /> 4. Work May proceed only at the direction of the inspector. To <br /> request an inspection of completed work, call 588-7984 <br /> (24-~our line) prior to 7:88 a.m. to receive same day <br /> service. <br /> 5. Provide at least 1 square foot of underfloor ventilation <br /> for each 150 square feet of crawl space area. The openinqs <br /> shall be covered with a corrosion resistant wire Mesh. A[ <br /> least one such opening shall be provided within 3 feet of <br /> each corner of the bu[ldinq. (R-311.1) <br /> ~. Provide an access crawl· hole to the underfloor space. The <br /> minimum size opening required is lB inches by 24 inches. <br /> (R-311.2) <br /> 7. A minimum 3' x 3' landing shall be required on each side of <br /> an egress door. The floor or landing shall not be More <br /> than one and one-half inches lower than the top of the <br /> threshold. (R-212) Exception: The landing on the <br /> exterior side of an exterior doorway shall not be More than <br /> 8 and one-half inches below the top of the threshold. <br /> 8. Stairways shall not be less than 3 feet in clear width and <br /> the headroom shall not be less than ~ feet 8 inches. The <br /> minimum required stair tread width ~s ? inches. The <br /> MaXimUM stair rise is 8 1/4 inches. When risers are <br /> closed, all treads mpy have a uniform projection not to <br /> exceed 1 and 1/2 inches. The greatest riser height shall <br /> not exceed the smallest by More than 3/8 inch. (R-213.1) <br /> 9. Handrails Meeting the following requirements shall b~ · <br /> provided on at least one side of stairways. The hanogrip <br /> .portion of handrails shall be not More than 2 5/8 inches in <br /> cross-sectional dimension, or the shape shall provide an <br /> equivalent gripping surface. Handrails shall be Mounted <br /> between a Minimum of 30 inches and a Maximum of 38 inches. <br /> They shall be continuous the full length of the stairs. <br /> Ends shall be returned or shall terminate in newel posts or <br /> safety terminals. <br /> (R-214.1) <br /> 10. Porches, balconies or raised floor surfaces located More <br /> than 38 in. above the floor or ~rade shall have quardrail <br /> not less than 36 inches in heig§t. Required guar~rail shall <br /> have intermediate rails or ornamental closures which will <br /> not allow passage of an object 6 in. or ~ore in diameter. <br /> Horizontal spacing between the vertical Members in required <br /> <br /> <br />