Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 ° Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 ° 24-HR Inspection Line: (503) 588-7904 <br /> <br />DATE/TiHE <br />TYPE <br />OC~PAHCY <br /> <br /> HAHUFACTURED DHELLIHG PERHIT <br /> = B2/2~/96 13=19 PERHIT HO : 96-~987 <br /> = Hem Hanufactured D~mlling STATUS = ISSUED <br /> = R-3 ISSUED : ~2/2~/1996 <br /> TO EXPIRE = B8/18/1996 <br /> PAGE 3 <br /> manufactured dwelling ready for occupancy. Assigned street numbers shall be <br /> painted or affixed to the front of the dwelling in a contrasting and, highly <br /> visible co]or, not less than four (4) inches in height. ' <br /> <br /> This inspection includes checking construction and code requirements for decks <br /> and steps, skirting and underfloor ventilation and access. <br /> <br />A REINSPECTION FEE OF $&0.00 shall be assessed for each inspection beyond the <br />permitted three inspections or (1) when the permit card is not posted <br />on the job site; (2) for failure to provide access on the date roi" which ' <br />the inspection is requested; (3) when the work for which an inspection is <br />requested is not com@lete~ (4) when the manufufactured dwelling is not installed <br />per 1996 Manufacture~ Dwelling Standards, or (5) when re§uired'corrections are <br />-not made. No inspections will be performed until the reinspection 'Fee has been <br />p~id at our office. <br /> <br /> OTHEH COMME'NTS'""~ND CONDIIIONS <br /> <br /> 1. THIS PLAN REVIEW WAS COMPLETED ~Y S. FREILINGER ON 2/2~/96. <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of Io~al government. <br /> 3. A roadside marker shall be placed at the access point with <br /> address numbers in a contrasting and highly visible color, <br /> not less than three (3) inches in height. <br /> 4. Work may proceed only at the directio~ of the inspector. To <br /> request'an inspection of completed work, call 588-79~4 <br /> (24-~our line) prior to 7:00 a.m. to receive same day <br /> serv1ce. <br /> 5. Provide at least I square foot of underfloor ventilation <br /> for each 150 square feet of crawl space area. The openings <br /> shall be covered with a corrosion resistant wire mesh. <br /> least one such opening shall be provided within ~ feet of <br /> each corner of the building. <br /> 6. Provide an access crawl hole to the underfloor space. 'The <br /> minimum size opening required is 18 in~hes by 24 inches. <br /> (R-~ll.2) <br /> 7. A minimum.3' x J' landing shall be required on each side of <br /> an egress door. The floor or landing shall not be more <br /> than one and one-half inches lower than the top of the <br /> threshold. (R-212) Exception: The landing on the <br /> exterior side of an exterior doorway shall not be more than <br /> ~ ~nd one-half inches below the top of the threshold. <br /> 8. St~rwa×s shall not be less than 3 feet in clear width and <br /> the headroom shall not be less than 6 feet 0 inches. The <br /> minimum required stair tread width is ? inches. The <br /> maximum stair rise is 8 1/4 inches. When risers are <br /> closed, all treads may have a. uniform projection not to <br /> exceed 1 and 1/2 inches. The greatest riser heiaht shall <br /> not exceed the smallest by more than ~/8 inch. ZR-21J. 1) <br /> 9. Handrails meeting the following requirements shall be <br /> provided on at least one side of stairways. The handgrip- <br /> portion of handrails shall be not more than 2 5/8 inches in <br /> cross-sectional dimension, or the shape shall provide an <br /> equiwlent gripping surface. Handrails shall be mounted <br /> between a m~nimum bf ~0 inches and a maximum of ~8 inches. <br />  h~y shall be continuous the full length of the stairs. <br /> nos shall be returned or shell terminate in newel posts or <br /> safet~ terminals. <br /> (R-214.1) <br /> 10. Porches, b~lconies or r~ised floor surfaces located wore <br /> than JO in. above the floor or grade shall have guardrail <br /> not less then ~6 inches in height..Required guar~rail shall <br /> have intermediate rails or ornamental closures which will <br /> not ~llow pass,ge of an object ~ in. or wore in diameter. <br /> Horizo~r~e] sp~cing between the ver'~ical members in required <br /> <br /> <br />