Laserfiche WebLink
Marion <br /> <br /> OREGON <br />COMN~UNITY DEVELOPMENT <br />O~PARTMENT <br /> <br />K~T~LU~ec~ION F,I/POR~ FOR ~ <br />0~-~T~ SEWAGE DI$~OSP~ <br /> <br />august 15, 1994 <br /> <br />K~N & SANDY ALLEN <br />7927 STONEFIELD CT SE <br />AUMSVILLE, OREGON 9732~ <br /> <br />SUBJECT: <br /> <br />SITE $94-284~, <br />SITE ADDI~SS~ <br /> <br />FILE <br /> <br /> T~85~ R=2W, $:26C, NORTH ~O. T/L: 2300 <br />7925 STO~EFIELD CT SE. AUMSVILLE, OR 97325 <br /> <br />An evaluation has been made of the above described property proposed for <br />installation Of an eh-Site sewage dispoca% syst~. As a result of that <br />investigation, it has been determined that the site specified on your appliCa- <br />tion does not quallfy for a standard Septic system or ~y of the alternative <br />system~. The conditions on the site do not meet the minimum requicements of <br />the Department of E~vironmental Quality O~-Site S~wage Di~sal Rule~. These <br />r~les are s~cified in Oregon A~istrative Rules, Chafer 340, Division 71, <br />Suctions 100 ~hrough ~00, ~nse~ly, this site must b~ denied. <br /> <br />The principal reasons for d~nial of %his site are related ~o shallow seasonal <br />water tables. Th~ following paragraphs outline the s~ecifie reasons for this <br />denial. <br /> <br /> WATER TABLES: <br /> 1. A water table, as indicated by sonditions associated with satura- <br /> tion, was observed On the property as follows: <br /> a. Evidence of a $~asonal....wa~e~ table wa~ observed at ~ to 32 <br /> inches belOW the ground surface. Thes~ measurements were to <br /> the depth of the sell ~tling or to the actual d~pth of an <br /> ebserved water table. <br /> 2. The above oonditloms do not meet the minimum D.E.Q. rules pertaiu- <br /> lng to standard and alternative sewage systemS, The minimum <br /> requirements are listed belOW: <br /> a- A seasonal ~roundwa~er table cannot be less than ~Q~inches <br /> below the ground surface for installation of a standard <br /> septic system or 36 i~c~gs for installation of any of the <br /> alternative systemc. <br /> <br />If you disagree with this evaluation, you may apl~eal to D.E.Q. A request may <br />b~ submitted to the D.E.Q, ~or a denial review and they will visit the <br />prope=ty and make a determina~ioB on the suitability of your site for instal- <br />lation of an on-site sewage disposal syst~. Application must be made to the <br />Willamette valley Regional Office of the D,E.Q. within thirty (30) days of <br />denial notification, D.E.Q. will cha~ge a fee for this inspection. <br /> <br />Please call our office if you have any questions. Our hours a~e 8so0 to 4:30, <br />Monday through F~tday. <br /> <br />MARION COUNTY BUILDING INSPECTIONS <br /> <br /> <br />