Laserfiche WebLink
July 11, 1994 <br /> <br />APPLICAET= <br />SITE NUMB~R~ <br /> <br />RICK GOM~S, <br />94-2158, NW P/O T/L 3400 <br /> <br /> YOur site has l~en found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SYST~. The following construction specifications shall apDly to the installa- <br />tion of your septic System. <br /> <br /> 1. The septic tank ~hall have a minimum liquid capacity of ~ <br /> ~ gallons. <br /> <br /> 2. The projected daily sewage flow for this project is calculated at <br /> 450~a~llons Der da~. Based on soil conditions observed on this <br /> site, =he dispesal field will be sized at 1S0 lineal feet De.~.150 <br /> qallons Of projected daily sewage flow. A minimum of ~ <br /> feet of disposal field will be required for your proposed develop- <br /> ment. The disposal trenches are constructed two (2) feet wide and <br /> on minimum ten (10) foot centers and with no line exceeding 125 <br /> feet in length. The trenches and perforated pipe are installed <br /> level (tl') and contoured ko follow the natural ground surface. <br /> <br /> 3. The disposal field shall be eenst~cted with serial diG~r~butien <br /> with a minimum trench de~th o~ ~4 inches and a maximum trench <br /> depth of ~4 inches, There must be at least ~ inches of backfill <br /> ever the tOD ef the gravel, measu~e~ from the natural ground <br /> <br /> An ~ffluent lift pump may be uecesaary to construct the disposal field <br /> in the approved area and at the eormect depth. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the <br /> <br />sPEcIAL CONDITIONS: <br /> Construct the original drainfield as far up.lOpe aS pOSsible within the <br /> Southwesterly par~ of the property. Avoid the n0~the~ly concave land- <br /> form. A pre-permit field stakeout will be necessary to establish the <br /> locations and elevations of the individual drainf£el~ lines of both <br /> systems. I~mfer to the enclosed stakeout procedure an~ the s~tbaek llst <br /> for details to complete the stakeout. Defer any exuavatien and siting <br /> all wells-until the drainfield locations are confirmed. Use care not to <br /> alter the natural topsoil prior to drainfield construction. <br /> space for a future curtain drain above the drainfields should it prove <br /> <br />THIS i.~.....N~.....A, pErMIT TO IN$~A?~. T~ S~PTiC S~STEM, DO N~IN~TBYJ~ TEE <br />UNTIL A VALID PERMIT ~ ~N ISS~I) BY T~IS OFFICE . <br /> <br /> <br />