Laserfiche WebLink
IMA~£ALLATION OF 1,000 GALLON AND 1,500 GALLON SEPTIC <br />TANKS AND DOMING-SEPTIC TANE$ <br /> <br />ALL TANKS must be set level on undisturbed earth o~ sand beddlng <br />~o prevent settlelng. Use 3/4" Kent Seal #2 or approwed equal <br />so ~eal all field joints. If joints mus~ be disturbed, replace <br />all old Kent Meal with new material. If Kent Seal is unavailable, <br />an acceptable subs$1tute is grou~ made with hydrollc eemen~ <br />mixed lm the specified proportions. <br /> <br />ALL dosing-septic Sands should be water ~eSted when ln~$~lled, <br />before back~fillln~ and before hooklmg up $o Sewer pipe, to <br />test ~or leakage and ~o preve~ floating in high wa~er areas. <br /> <br />2'LOAT level control~ in 1,0O0 gallon doslng-septlc tank are to <br />be se~ as follows: <br /> <br /> With regar4 to the pump controls, a 4 inch cycle is required for all new <br /> single family dwelling building sites. Thi~ is a minimum criteria for <br /> standard systems, but a maximUm criteria for those systems utilizing <br /> pressurized d%stribution. Based upon the original engineering ~pecifi- <br /> cations for the dosing~septi¢ tank, the off-level can be no greater than <br />%41-5 ihches from the bottom of the tank~ Measuring from the top exteri.- <br /> or of the tank, the off-level would then measure 21.§ inches. This way, <br /> as according to DEQ rules, the tank would have a remaining capacity <br /> after*cycle of 900 gallons~ With a 4 inch Cyo!e, the pump on-level <br /> would then measure 17.5 inches, again measured from the top exterior <br /> edge of ~he tank. With re~ard to the alarm, which has.been the compo- <br /> nent of the p=eset controls found to be out of coordination, for teaser, s <br /> of providing some level of storage volume within the tank, an operating <br /> level of 15 inches has been established. In this way, a zone between <br /> the pump on-level and the alarm of 1.5 inches can be maintained and at <br /> least 3 inches or approximately 6~ gallons of storage volume can be <br /> provided %]pon alarm signal. To make things simpler for the construction <br /> ~ndustry, we have b~en operating on the following measurements~ <br /> <br />Pump Off 21 inches; Pump On - 17 inches, Alarm'- .]5 inches. <br /> <br />all of which are measured from a straight edge~ laid across the top <br />exterior of the tank. where the OreDco bucket Js used, we bare ad~d <br />factor of 1 inch to account for the raised edq~ of the b~cket which <br />~ould increace each of these measurements accordingly. <br /> <br />Measurements for 1,500 gallon tank from top of tank are the came, <br />only ~he remaining capacity changes.* <br /> <br />Note to home owners: ALL tanks should be pumped every five (5) <br />years for ~he average family of five (J). This is go prevent <br />serious sludge damage tO the leach fields. <br /> <br /> <br />