Permit Address
3871 LANGLEY ST SE
Permit City
Salem
Permit Number
555-23-004402-STR
Parcel Number
082W18B 02400
Permit Type
Structural
Extra Information
Alternate Material(s)and/orMethod(s) Application
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Structural Design Calculations under Fire Conditions 1 :X dt " i=l,! 'r ri5 <br /> When utilizing the char calculation option of NDS Chapter <br /> 16 to demonstrate fire-resistance ratings,a structural design Beduclamm Mara"Wiefff Depth pus? <br /> check must also be done to determine structural adequacy } � <br /> of framing members under fire conditions. One of the main --. <br /> benefits of the char calculation method is that it accounts for _.. <br /> the ability that heavy and mass timber have to form a char ', ( <br /> zone,which insulates the remaining wood cross-section, • <br /> allowing it to retain structural capacity. • """'" "_"'"' : ° a s <br /> NDS Section 16,2.2 states that, under fire design conditions, , l £ i <br /> the average member strength can be approximated by <br /> multiplying reference design values such as Fb by the `-""t <br /> adjustment factors specified in Table 16.2.2. As indicated .-' r <br /> in Table 7,an increase in allowable design stresses by a factor <br /> ranging from 2.03 to 2.85 is allowed, depending on the stress <br /> 'Fn 'u I9 "' ' Saw�xN pBC under consideration. +t"� <br /> For example, a 6-3/4-inch x 13-1/2-inch glulam beam with <br /> an unadjusted allowable bending stress of 2,400 psi would <br /> first be checked for all structural loading conditions and limit <br /> states(bending,shear,deflection,vibration and others as TABLE 6: <br /> applicable)using the full cross-sectional dimensions and Effective Char Rates and Char Depths <br /> adjustment factors per NDS Chapter 5. If this beam were (tor 8, = 1.5 inches/hour) <br /> required to have a 1-hour fire-resistance rating(perhaps as n +e Ex a <br /> a floor beam in a Type V-A structure)then its effective char <br /> depth on all three exposed sides would be 1.8 inches(per <br /> tr <br /> NDS Table 16.2.1A). Its cross-sectional dimensions under • a <br /> fire conditions would be: 1 215 <br /> .1 <br /> Width = 6.75•-(2111.8') =3.15' 1-1/2 .1 <br /> 2 2.6 <br /> Depth = 13.5'-1.8" = 11.7' <br /> Source NOS Table 162IA,AWC <br /> This reduced cross-section would then be checked under <br /> fire conditions,with allowable design stresses increased <br /> by the factors given in NDS Table 16.2.2. For example, a TABLE 7: <br /> 2.85 increase factor could be applied to allowable bending Member Strength Adjustment Factors <br /> stresses.AWC's TR 10 provides design examples for a <br /> number of exposed timber applications under fire conditions <br /> The stress adjustment factor, K,to increase the reference <br /> design stress is for use when performing a structural capacity Bending strength 2.85 <br /> check under the fire load condition with allowable stress Beam bucking strength 2.03 <br /> design (ASD) load combinations le.g., D + L,etc.). This stress Tensile strength 2.65 <br /> adjustment factor is not intended to be used with load and <br /> resistance factor design ILRFD)load combinations,including Compressive strength 2.58 <br /> those intended for extraordinary events such as in ASCE 7-16 Column buckling strength 2.03 <br /> Section 2.5. Shear strength 2.75" <br /> Source:NOS Table 16.1.1 AWC <br /> *From TR 1O Table 4.1.2,not the NOS <br /> J <br /> 5 <br />