My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13008198
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
18-XXXXXX
>
13008198
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:00:19 PM
Creation date
8/6/2025 3:47:59 PM
Metadata
Fields
Template:
Permits
Permit Address
3012 WILTSEY ST SE
Permit City
Salem
Permit Number
555-18-004112-STR
Parcel Number
083W24B 00100
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
In lieu of fire sprinklers the following site considerations, fire/life/safety&construction <br /> upgrades are proposed: <br /> -the building has yards in excess of 60'on 3 sides,20' on the east wall of Phase I. <br /> -the building has(4)accessible exits and a total of(7)-36"exit doors. Kitchen has it's own 36" <br /> exit. (3)-36"exit doors are the minimum required per the occupant load. The maximum travel <br /> distance is less than%the maximum allowable of 200',Table 1016.2. <br /> -a fire alarm system that will include manual pull stations and strobes as required by Code but <br /> will be upgraded to include smoke detection to activate alarms. <br /> -5/8"Type-X gypsum board to be used on all walls and exposed ceilings. <br /> -suspended ceilings in the dining&assembly are class A. <br /> -the common wall between the assembly&dining room will be finished with(1)-layer 5/8" <br /> Type-X gypsum board each side. One side to be sheeted with'A"plywood/osb as part of the <br /> lateral design. The plywood will extend from the floor to the roof sheeting forming a draft stop <br /> &smoke partition(Section 710)as well. The door in smoke partition is to be self-closing with <br /> smoke gaskets. No duct penetrations are anticipated through this wall. <br /> -class B membrane roofing system. <br /> REASON FOR THE PROPOSED ALTERNATE: <br /> The water supply required to support an automatic sprinkler system is not available& <br /> impractical at this rural site. The cost of providing fire sprinklers and a water supply to meet the <br /> NPPA 13 requirements would not allow this project to proceed.The Temple members did not <br /> anticipate a project this large when they started Phase I. Increased enrollment and interest are <br /> now driving this expansion.No further expansion of this building will be possible or is <br /> anticipated. <br /> CONCLUSION: <br /> This proposal follows the guidelines outlined in the State of Oregon"White Paper"dated <br /> February 2016. It is the Temple's intent that the proposed alternate above complies with the <br /> intent of the Code&these proposals will provide their membership safe&shorter paths of <br /> travel with additional exits. Upgraded 5/8"fire code gypsum board throughout the building on <br /> walls and ceilings for added framing fire protection. The enhanced fire alann&detection system <br /> will also provide prompt notification to both the building occupants and the fire department. <br /> Should this proposal be deemed"insufficient"the owner&Architect would consider other <br /> safeguard measures provided they are not cost prohibitive. <br /> END OF ALTERNATE METHODS PROPOSAL <br /> J <br />
The URL can be used to link to this page
Your browser does not support the video tag.