Laserfiche WebLink
BACKSTOP® NT TM DS455 <br /> A High Performance, Polymer-Based, Noncementitious <br /> v Water-Resistive Membrane and Air Barrier <br /> Description Coverage Acceptable Substrates <br /> Backstop NT is a flexible, polymer- Backstop NT-Texture and All sheathing substrate joints must <br /> based, noncementitious,air/water- Smooth are supplied in a 5 gal be treated with Dryvit Grid Tape <br /> resistive barrier,which resists (19 L) pail. Backstop NT-Spray and Backstop NT-Texture prior to <br /> water penetration, eliminates air is supplied in a 5 gal (19 L) pail or application over the full sheathing <br /> infiltration, and is vapor permeable. in a 55 gallon (280 L)drum. surface.Acceptable substrates <br /> It is classified as a Class III vapor Coverage will vary, depending on include: <br /> retarder over vertical above grade application method and substrate. a. Core treated exterior grade <br /> walls. Backstop NT is available in For guidance refer to the usage gypsum sheathing meeting <br /> three versions: chart included in this document. ASTM C 1396(formerly C 79). <br /> • Backstop NT-Texture is b. Core treated exterior grade <br /> applied using a trowel, roller, Properties gypsum sheathing with <br /> or texture spray equipment. Working Time-Backstop NT- fiberglass mat facers meeting <br /> • Backstop NT -Smooth is Texture, Smooth and Spray are ASTM C 1177. <br /> applied by roller or texture noncementitious, water based c. Exterior fiber reinforced cement <br /> spray equipment. materials and will not set-up in the or calcium silicate boards. <br /> • Backstop NT -Spray is pail. Keep pail covered when not in d.APA Exterior or Exposure 1 <br /> applied by airless spray use to minimize skinning. Rated Plywood, Grade C-D or <br /> equipment. Drying Time-The drying time is better, nominal 1/2 in(12.7 mm) <br /> dependent upon the air minimum, installed with the C <br /> Uses temperature,wind conditions and face out. <br /> Backstop NT-Texture, Smooth relative humidity. Under average e. APA Exterior Grade Fire <br /> and Spray are designed for use drying conditions[70 °F (21 CC), Retardant Treated Plywood, <br /> with Dryvit EIF Systems as well as 55% R.H.], Backstop NT will be dry nominal 1/2 in (12.7 mm) <br /> other building cladding systems. to the touch within 2 hours and minimum, installed with the C <br /> ( When used with the Dryvit cure in 6 hours. face out. <br /> v AquaFlash®System or Dryvit f.APA Exposure 1 Rated OSB, <br /> Flashing Tape TM, Backstop NT Testing Information nominal 1/2 in(12.7 mm) <br /> provides an effective air barrier For test data refer to the chart minimum. Note:Applications <br /> and water-resistive membrane for included with this document. over OSB sheathing requires a <br /> acceptable substrates. minimum of 2 coats of <br /> Application Procedure For Backstop NT-Smooth or <br /> Benefits complete application Spray.Backstop NT-Texture <br /> Backstop NT is a low VOC water- instructions, refer to, DS181. is not recommended for the <br /> based product used straight out of field of wall application over <br /> the pail after an initial spin up to Job Conditions OSB. <br /> provide a continuous membrane Air and surface temperature for 9 Unpainted, unsealed concrete <br /> with ease of application. The liquid application of Backstop NT must and CMU. <br /> applied coating dries quickly and be from 40 °F (4 °C) minimum to Surface Preparation <br /> serves as an excellent surface for 100 °F(38 °C) maximum and must <br /> adhesively attaching EPS. remain so for a minimum of • Sheathing board gaps shall not <br /> Backstop NT is seamless and will 12 hours. exceed 1/4 in (6.4 mm)and the <br /> not tear. Additionally, it is stable surface must be flat within 1/4 in <br /> under air pressure differences and Temporary Protection (6.4 mm)in any 4 ft(1.2 m) <br /> will not be affected by wind. Shall be provided at all times until radius. CMU mortar joints shall <br /> membrane is dry and shall not be be struck flush(tooled mortar <br /> Packaging exposed to weather for longer than joints and heavily textured CMU <br /> Backstop NT-Texture and 180 days prior to installation of the [not split faced] shall be <br /> Smooth are supplied in 5 gal specified cladding. skimmed with Dryvit Genesis®, <br /> (19 L) pails. Backstop NT- Spray Genesis®DM or Genesis®DMS) <br /> is supplied in a 5 gal (19 L) pail or prior to application of the <br /> in a 55 gallon (280 L)drum. Backstop NT-Texture or Spray. <br />