13007092
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
18-XXXXXX
>
13007092
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:00:20 PM
Creation date
8/6/2025 1:49:49 PM
Metadata
Fields
Template:
Permits
Permit Address
8226 RAUSCHER LN SE
Permit City
Aumsville
Permit Number
555-18-001198-STR
Parcel Number
081W33B 05000
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> 'I><il' F1346 — 91 (2018) <br /> such as keys, combination locks, special tools, devices, or 7.4 Opening Tests—The tests shall be conducted by the test <br /> inaccessible locations, and the like, to inhibit children under method described in 9.4 to demonstrate that any opening in the <br /> five years of age from removing or operating the cover.When major component or between the edge of the cover and the <br /> subjected to the load and perimeter deflection tests described in deck surface or coping wall,or both,and the top surface of the <br /> 9.1 and 9.2,all fastening devices shall remain in their intended, pool or the top surface of the spa is sufficiently small and <br /> secured or closed,or both,position.After the test,the intended strong to prevent the opening from being forced to a size that <br /> performance of the device should not be impaired. will allow the test object to pass through. <br /> 6.5 Openings—The cover shall be designed in such a way <br /> that, when it is tested by the test method described in 9.4,any 8. Minimum Label Requirements for All Covers for <br /> opening in the major component or between the edge of the Swimming Pools, Spas, and Hat Tubs <br /> cover and the deck surface or coping wall,or both,and the top 8.1 Product Label—All covers shall be labeled/marked to <br /> surface of the spa or pool does not allow the test object to pass identify manufacturers or other responsible parties (such as <br /> through.The test object shall not gain access to the water,or be private label distributors), or both. Labels attached to covers <br /> subject to entrapment. shall meet the general requirements described in 8.5.1 and 8.8 <br /> 6.6 Seams,ties or welds in the cover shall show no signs of — 8.8.2. <br /> damage, which will impair intended performance of the device 8.2 Warning Labels—AN covers shall be required to have <br /> when the cover is tested by the methods described in 9.1 —9.4. attached the following warning label: <br /> 8.2.1 Signal Word—WARNING. <br /> 7. Performance Requirements for Safety Covers 8.2.2 Safety Alert Symbol—Preceding the signal word there <br /> 7.1 Static Load—In the case of a pool with a width or shall be triangle with an exclamation point inside the triangle. <br /> diameter greater than 8 ft(2.4 m)from the periphery,the cover 8.2.2.1 Word Message—The standard word message shall <br /> shall be able to hold a weight of 485 lb(220.0 kg)(2 adults and be AVOID DROWNING RISK which shall be the first mes- <br /> 1 child) to permit a rescue operation. sage to appear directly under the signal word. <br /> 7.1.1 In the case of a pool with a width or diameter not 8.2.2.2 Additional Word Message Statement—Covers with <br /> greater than 8 ft(2,4 m)the cover shall withstand the weight of any of the outlined hazards in Fig. 1 shall list all applicable <br /> 275 lb (125 kg) (weight of a child and an adult). Compliance warning statements on the label. <br /> shall be determined by the test method described in 9.1. 8.3 Color—Non-safety cover warning label. <br /> 7.2 Perimeter Deflection—The cover shall be designed in 8.3.I Signal Word—Black letters with orange background. <br /> such a way that,when it is tested by the test method described 8.3.2 Safety Alert Symbol—Black triangle with orange ex- <br /> in 9.2, deflection of the cover does not allow the test object to clamation point. <br /> pass between the cover and the side of the pool, or to gain 8.3.3 Word Message—Black lettering on white background <br /> access to the water. or white letters on black background. <br /> 7.3 Surface Drainage—The cover shall be so constructed, 8.4 Color—Safety cover warning label. <br /> or incorporate a system,or have an auxiliary system provided, 8.4.1 Colors assigned to the signal word panel may also be <br /> that when used in accordance with the manufacturer's used for the message word panel provided the panel colors <br /> instructions, shall drain substantially all standing water from contrast with the lettering of the label. This is applicable to <br /> the cover within a period of 30 min after cessation of normal covers conforming with the PSC and MSC classifications only. <br /> rainfall. Compliance shall be determined by the test in 9.3. 8.5 Warning Label—Letter size. <br /> "HAZARDANARNING STATEMENT CHART' <br /> If This Hazard Exists: Add This Warning Statement: <br /> 'WIII not support weight(as defined In this'p cllication)Nonsecured or 'Stay oil cover—will not support weight. <br /> improperly secured covers <br /> 'Concealment by slipping under cover Keep children away.Children or objects cannot no seen under cover. <br /> 'Drowning an tap of cover In accumulated surface water(as defined in this 'Remove Standing Water—ehild can drown on top of cover. <br /> specification) <br /> 'Concealment,Entrapment—Drowning under cover 'Remove coverts)completely before entry of bathers—entrapment possible. <br /> 'General requirement for all covers 'Nomsacured or improperly secured covers are a hazard. <br /> 'Option to above for SafetyCovers 'Failure to follow all instructions may result In injury or drowning. <br /> v 'Cover does not meet all requirements of this specification for PSC,MSC. 'This Is not a Safety Dover. <br /> FIG.1 Hazard/Waming Statement Chart <br /> Copyright by ASTM Intl(all rights reserved);Thu May 3 11 15.07 EDT 2018 3 <br /> Downloaded/printed by <br /> Paul Moore(Emerald Outdoor Living)pursuant to License Agreement.No further reproductions authorized. <br />
The URL can be used to link to this page
Your browser does not support the video tag.