My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13007067
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
19-XXXXXX
>
13007067
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:00:18 PM
Creation date
8/6/2025 1:39:34 PM
Metadata
Fields
Template:
Permits
Permit Address
3036 CONTINENTAL DR SE
Permit City
Turner
Permit Number
555-19-003036-STR
Parcel Number
093W12A 00700
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
F1346 — 91 (2018) <br /> 9.2.2 Perimeter Deflection Test Object—Test object shall be all equipment shall operate in accordance with cover manufae- <br /> 3.7 in.(0.09 m)by 5.7 in.(0.14 m)by a minimum 12 in.length turer's instructions. Thirty minutes after completion of this <br /> and a weight of 36.6 lb in an ellipsoidal shape. See Fig. 2, procedure, the cover shall pass the test method in 9.3. At all <br /> times during the procedure, maintain the pool level at the <br /> waterline. <br /> 9.4 Openings Test: <br /> 9.4.1 These tests shall be conducted to demonstrate that any <br /> openings remain small enough to prevent a small child's head <br /> from gaining access to the water. <br /> 111/ 3.70" 9.4.2 Openings Test Object—A solid faced sphere test object <br /> with a maximum breadth of 4.5 in. <br /> 9.4.3 Procedure—The cover shall be fitted in accordance <br /> with the cover manufacturer's instructions. The test object <br /> shall be placed at or into any existing opening and apply a force <br /> of 40 lb (plus or minus 1 pound) steadily to ensure the test <br /> object cannot pass through at the following critical openings: <br /> 9,4,3.1 Any opening between the edge of the cover and the <br /> 5.70" deck surface and coping wall,or both,or the top surface of the <br /> Nam. I—Area=16.6 in.2 spa or pool. <br /> Note 2—Perimeter=15.0 in. 9.4.3.2 Any opening in the major component of the cover. <br /> FIG.2 Template for Swimming Pool Cover Standard <br /> 10. Operating Controls, Safety Covers <br /> 9.2.3 Procedure—With 50 lb (22.7 kg) on the cover at a 10.1 The open-close switch shall be spring-loaded or of the <br /> distance of at least 4 ft,but not exceeding 6 ft from the side of momentary contact type,so that when released, the cover stops <br /> the pool, the same cover shall not deflect to allow a perimeter operation immediately at any point in the open or closed cycle <br /> test object to pass through, gain access to the water or be period. <br /> subject to entrapment between the cover and the side of the <br /> pool. 10.2 The cover shall be reversible in direction from a full <br /> stop at any point in its travel without having to complete the <br /> 9.3 Surface Drainage Test: full open or closed cycle. <br /> 9.3.1 Surface Drainage Test Object—Timmya or equivalent <br /> (32 in. length by 9 in. width by 5 in. deep by 36.6 lb 10.3 Electrically operated control switches and motors shall <br /> torso-shaped object) shall be placed on the pool cover in a be installed in accordance with the National Electrical Code <br /> supine position,faceup,within two to three feet of and parallel Article 680-26. <br /> with the poops edge.Three minutes later there shall not be an 10.4 The type of pool covering operating controls shall be <br /> unsafe amount of water.An unsafe amount of water is defined such that: <br /> as any quantity of water which completely covers the torso of 10.4.1 Its fixed location is in the line of sight of the <br /> the surface drainage test object. complete pool cover, or by its operating process.This ensures <br /> 9.3.2 Procedure—Test the cover by spraying water evenly that the operator shall be in complete view of the cover at all <br /> over the area at an application rate of 10 gal/rein per 1000 ft2 times during the closing or pool covering process. <br /> (9.29 m2)of pool area for a period of 30 min.During this test, 10.4.2 Switching devices shall be key-operated or locked <br /> away or able to be de-activated or otherwise located in an <br /> "'Ifmmy'is a CPR mannequin,torte year old boy;available from Simulaids inaccessible location. An inaccessible location shall be at a <br /> Inc.,P.O.Box 807.Dixon Avenue,Woodstock,NY 12189. height of at least five feet above the deck. <br /> Copyright by ASTM Inn(all rights reserved);Thu May 1 11.15 07 EDT 2018 5 <br /> DownloadeNprinted by <br />
The URL can be used to link to this page
Your browser does not support the video tag.