Laserfiche WebLink
intertek 130 Derry Court <br /> York,Pennsylvania 17406 <br /> Total Quality.Assured. Telephone: 717-7 64-7700 <br /> Facsimile: 717-764-4129 <br /> www.intertek.cam/building <br /> TEST REPORT FOR EASTMAN PERFORMANCE FILMS, LLC <br /> Report No.: 17039.10-119-37 <br /> Date:08/09/18 <br /> SECTION 10 <br /> TEST RESULTS <br /> Test Date:07/24/18 <br /> Lab Temperature:71°F <br /> Impact Drop Height:48 inches <br /> ari , <br /> 1 0.246 G No openings N/A N/A Pass <br /> 2 0.246 G No openings 38.Og 14.Og Pass <br /> 3 0.246 F No openings N/A N/A Pass <br /> 4 0.247 F No openings N/A N/A Pass <br /> 'impact Side: G=Glass Side Impacted F=Film/Organic Coated Side Impacted <br /> Acceptance Criterion: Limit <br /> No detached fragments over 1 in2. 9.17 grams <br /> t No single detached particle shall weigh more than 6.82 in2. 62.56 grams <br /> fir Total weight of detached particles>1 in2shall not weigh more than 15.5 in2. 142.19 grams <br /> No shear or opening through which a 3"sphere can freely pass with 4 lbs.force. <br /> Note 1:Acceptance criteria limits were calculated using the nominal glass thickness identified in <br /> the'Glazing Composition Details'section. <br /> Note 2:The'Limit'presented for each item in the 'Impact Test Acceptance Criteria'identifies the <br /> allowable weight of the particle/fragment size for the specified item in the'Criterion'section. <br /> SECTION 11 <br /> CONCLUSION <br /> The specimens meet the impact performance requirements set forth in the referenced test <br /> procedures. <br /> SECTION 12 <br /> REVISION LOG <br /> 0 08/09/18 N/A Original Report Issue <br /> (1111, <br /> Version:08/07/17 Page5 of 5 RT-R-AMER-Test-2889 <br />