Permit Address
545 3RD AVE N
Permit City
Stayton
Permit Number
555-21-006704-STR
Parcel Number
091W10DB10000
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
C. From shingle course to shingle course upwards on roof deck, end joints must be maintained with a horizontal <br /> offset of 5-5/8 inches. <br /> D. Ventilation: Provide minimum of 1 square feet of total net free ventilating area for each 150 square feet of <br /> ceiling area, or 1 square foot for each 300 square feet of ceiling area if either a vapor barrier is installed on <br /> warm side of ceiling area or if approximately one-half the ventilation is provided near roof ridge. <br /> 3.3 UNDERLAYMENT <br /> A. Roof decks with pitch of 4-inches per foot or greater,for new construction or when old roofing has been <br /> removed, apply a single layer of felt underlayment complying with ASTM D226, D4869 or D6757 and local <br /> building code. <br /> Specifier Note: For slopes at least 4-inches per foot, PABCO®recommends single layer felt underlayment. <br /> 1. [Single Layer Felt Underlayment: Apply underlayment with 2-inch wide top laps and 4-inch wide end <br /> laps. Lap felt underlayment a minimum of 6-inches from both sides overall hips, ridges and valleys.] <br /> Specifier Note: On slopes between 2 inches and 4 inches per foot, PABCO®recommends self-adhering underlayment or <br /> double layer felt underlayment. <br /> B. Roof decks with pitch of greater than 2-inches per foot and less than 4-inches per foot,for new construction <br /> or when old roofing has been removed, apply underlayment: <br /> 1. [Self-Adhering Underlayment: Apply self-adhering underlayment according to underlayment <br /> manufacturer's written instructions and in compliance with local building code.] <br /> 2. [Double-Layer Felt Underlayment: Apply a first course of underlayment with 19-inch wide top laps and <br /> 12-inch wide end laps. Over this, apply a full 36-inches wide sheet. Continue 36-inches wide sheets, <br /> lapping each 19- inches over the preceding course.] <br /> 3.4 EAVE FLASHING <br /> A. Install self-adhering underlayment as an eave flashing for ice dam protection in areas of winter temperatures <br /> averaging 30°F or less, applied parallel to the eave. Eave flashing overhangs drip edge 1/4-inch to 3/8-inch <br /> and extends up the roof to at least 24-inches inside the interior wall line. Horizontal (top)overlaps(when <br /> needed), should be located over the overhang area. Top laps are at least 2-inches, end laps are at least 6- <br /> inches. <br /> B. Eave Drip Edges: Install eave drip edge flashings below underlayment and fasten to roof sheathing. <br /> 3.5 NAILING INSTRUCTIONS <br /> A. Use four nails per shingle for normal application, positioned in the nail zone as recommended by shingle <br /> manufacturer. Nails shall be at least 1 inch long, aluminum or galvanized, 3/8-inch head, 11or 12-gauge <br /> roofing nails. Nails must be driven flush with shingle surface. NAILS MUST NOT BE OVERDRIVEN TO CUT <br /> INTO SHINGLES. <br /> Specifier Note: See the PABCO Tahoma® Application Details—Nailing Instructions for additional details at <br /> www.oabcoroofing.com. <br /> B. Special Applications: <br /> 1. High Wind Application: For areas where local knowledge indicates exposure to high winds may occur, <br /> shingles must be applied with 6 nails spaced according to shingle manufacturer's written instructions <br /> and sealed to qualify for wind damage warranty coverage. <br /> 2. Steep Slope Application: On slopes greater than 21-inches per foot(Mansard type roofs), 6 nails are <br /> required, spaced according to shingle manufacturer's written instructions.These shingles are to be hand <br /> sealed at the time of application with asphalt roof cement, by applying 6 spots about the size of a <br /> quarter, located under the shingle tab corners. <br /> 3.6 VALLEYS <br /> Specifier Note: Closed-cut valleys are recommended by PABCO®; woven valleys are also accepted. <br /> A. Closed-cut Valleys: <br /> 1. Valley Flashing: Valley starts with 36-inches self-adhered, bottom layer underlayment centered down the <br /> valley. Extend felt underlayment from the field over this and trim overlap 6-inches. A second <br /> underlayment layer(ASTM D4869 Type II or heavier) is applied over this, centered down the valley. Lay <br /> the first course of shingles along the eaves of one roof plane and over the valley, extending it into the <br /> Project Name/Project Number/Insert Date Revised 11/17/20-Page 5 ASPHALT SHINGLES <br /> PABCO®Roofing Products <br />