My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13000882
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
13000882
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2025 8:00:17 PM
Creation date
8/5/2025 12:13:16 PM
Metadata
Fields
Template:
Permits
Permit Address
10226 MARION RD SE
Permit City
Turner
Permit Number
555-22-003476-STR
Parcel Number
092W10 00200
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Application Procedures Cleanup & Safety <br /> t e Film Thickness Frequent measurements with a wet film Cleanup Pump,Gun,Tips,Hoses,and Mixers should be cleaned once per <br /> Mgauge are recommended during the application day with clean water. <br /> process to ensure uniform thickness Safety It is recommended protective equipment should be worn when <br /> applying Fireguard',including spray suits,eye protection, <br /> gloves,and respirators.Refer to Fireguard'Material Safety Data <br /> Dry Film Thickness Final thickness must be measured using an Sheet. <br /> electronic dry film thickness gauge such as a Ventilation Ventilation should not be less than 4 complete air exchanges <br /> PosiTector 6000.For method of thickness per hour until the material is dry. <br /> determination and tolerances refer to:AW CI <br /> Technical Manual 12-B(standard practice for the Maintenance <br /> testing and inspection of field applied thin film <br /> intumescent fire resistive materials). <br /> General If coating becomes damaged,rebuild required thickness by <br /> spray or trowel.When dry,smooth and finish with topcoat to <br /> match.Damaged areas must be abraded back to a firm edge by <br /> sanding or scraping.The topcoat should be abraded back 1" <br /> Application Equipment Guidelines (25.4 mm)from the damaged area.The surface must be clean <br /> and dry before applying Fireguard'. <br /> Listed below are general equipment guidelines for the application of this product when <br /> spray applied. Testing/Certifications <br /> Airless spray Airlessco LP540 or equivalent <br /> Uncertainty Measurement in Guardian's fire testing is less than 1%as per <br /> Spray Gun Standard airless spray gun ASTM E 2536-06. <br /> Spray Tips 0.019"-0021 Guardian is accredited and meets the requirements of lSO/IEC 17025 as <br /> verified by ANSI/ASO National Accreditation Board/A CLASS.Refer to <br /> Fan Size 4"-10"(depending on section being sprayed) certificate and scope of accreditation report AT1247.Guardian also is <br /> accredited as an inspection agency per ISO 17020 through ANSI/ASQ <br /> Hose Length 150'(45m) National Accreditation Board/ACLASS,Report 1547. <br /> 'teriai hose ------ 3/8"(9.25mm)I.D.minimum N.B.:ANSI/ASO/ACLASS is a signatory member of the International <br /> Laboratory Accreditation Cooperation's(ILAC)Mutual Recognition <br /> Whip Hose 'A"(6.35 mm)I.D minimum(optional) Arrangement(MRA). <br /> ANSI/ASQ/ACLASS accreditation of Guardian ensures global recognition for <br /> Guardian's services. <br /> Application Conditions <br /> Storage, Packaging& Handeling <br /> Condition Material Surface Ambient Humidity <br /> Shelf Life l year from production date <br /> Minimum 70°F(21'C) SO'F(l(t) SOT MT) 0% •Shelf Life:(actual stated shelf life)when kept at recommended <br /> Maximum l00'F(38T) 125°F(52'C) llo°F(43'Q 85% storage conditions and in unopened original container. <br /> *Steel surface temperature should be a minimum of 5'F (3Q above the dew point. <br /> Fireguard must be protected from exposure to weather.Protect from freezing. Shipping Weight approximately 12 lbs per gallon(1.44 kg/1) <br /> Storage Store indoors in a dry environment between 33'F-100'F(1'C- <br /> Curing Schedule 38°q.Protect from freezing. <br /> • <br /> Packaging <br /> Surface Temp.&50%Relative Dry to Recoat <br /> Humidity 5 Gallon 55 Gallon Tote <br /> D'F(25'C) 24 Hours Are'Relvai <br /> ,1t is recommended to apply one coat 25-30 mils wet per day.Drying time will vary with 7.'17 <br /> 11.1. <br /> temp. Thinner coats as well as air movement will help drying time. Another coat of <br /> Fireguard'can be applied when previous coat has a Shore D hardness of 50 measured at r , <br /> 20'F(21°C).It can be top coated when a hardness of 60 is achieved after a 4-5 day cure ,,1` WOO <br /> time.May 2015. <br /> This technical data sheet was designed incorporating information to the best of knowledge that was true and accurate on the date that this information was published.No guarantee of accuracy is given <br /> or implied.We guarantee our products to conform to Shield Industries quality control.No other warranty of any kind is made by Shield Industries,Inc. To determine needs for specific application and <br /> correctness of use it is important to reference manufacturer specification sheets and contact Shield Industries directly.parcel-Me,FireGuard"&FireGuard E04'are registered trademarks of Shield <br /> Industries,Inc <br /> Shield Industries,Inc. <br /> 131 Smokehill lane.Woodstock,GA 30188 (770)517-6869 <br />
The URL can be used to link to this page
Your browser does not support the video tag.