My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13000178
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
13-XXXXX
>
13000178
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2025 8:00:11 PM
Creation date
8/4/2025 3:57:40 PM
Metadata
Fields
Template:
Permits
Permit Address
352 REES HILL RD SE
Permit City
Salem
Permit Number
555-13-01941
Parcel Number
083W21DD00700
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Table 2. Hot-Box Test Results for Wood and Steel-Framed Wall Assemblies with Studs 16 in.(40 cm)O.C. <br /> Wall Configuration Wood Stud Wall Steel Stud Wall Steel Stud Wall <br /> Base 16 in.(40 cm) Base 16 in.(40 cm) 0.75 in.(1.9 cm)XPS <br /> Clear Wall R <br /> (Hot Box Test) 9.65(1.69) 5.78(1.02) 9.37(1.65) <br /> @4t2-°F/Btu[m2K/W]) <br /> Center f Cavity 13.95(1.76) 13.95(1.76) 17.95(3.16) <br /> R-Value(h.ftc.°FBtu[m K/W]) <br /> %Difference in 30.8% 58.6% 47.8% <br /> R-Values <br /> WALL CONFIGURATIONS USED FOR THERMAL - --- -3,--� <br /> ANALYSIS l <br /> i <br /> A series of finite difference simulations were performed <br /> on 2x4(5.1x10.2-cm)wood and steel-framed walls.The first <br /> wall specimen was a copy of the framing configuration which I <br /> is traditionally used in hot-box testing.As shown on Figure 3 I <br /> the test specimen contains wood studs Stalled 16-in.(40-cm) ! !! (. <br /> o.c.with single top and bottom plates.This wall has a framing ' I <br /> factor of about 14%. <br /> At the present time, several state energy authorities are ' <br /> considering incorporation of findings of the 2002 CEC and I Le <br /> 2003 ASHRAE studies (CEC 2001A,CEC 2001B) into the I <br /> local energy performance requirements.Unfortunately,many 1 I <br /> of these codes only characterize requirements for cavity insu- 16 -j <br /> lation or a R-value/U-value through the insulation without <br /> consideration of the framing intensity or framing materials.It — --� -----8'- --- ---is a very incomplete approach!As shown in Table 2,two walls <br /> of the same in-cavity R-values may have significantly differ- Figure 3 Schematic of an 8 x 8)9(2.44 x 2.44 m)test wall <br /> ent clear wall R-values. with 16 in. spacing. <br /> The amount of framing counts in thermal performance <br /> analysis. That is why new recommendations are needed for Figure 7 shows a wall configuration with 14 studs <br /> framing material configurations in hot-box testing-to incor- centrally located. There are 2-in. gaps between each two of <br /> porate framing factors of 25% or more. To study increased centrally-located studs. This configuration was used to <br /> levels of framing within 8-ft.by 8-ft(2.44-m by 2.44-in)test analyze the effects of missing insulation in areas of high <br /> walls, six wall configurations (three wood-frame and three concentration of structural members. <br /> steel-frame walls) were analyzed to determine the effect of On the wall configuration as presented on Figure 7,spaces <br /> stud placement on the clear-wall R-value calculation. These between studs can be empty or filled with the insulation. To <br /> configurations-are shown in Figures 4,5,and 6. <br /> further evaluate the effect of a series of these 2-in. (5.1-cm) <br /> Figure 4 shows example of the wall, where studs are wide spaces between individual studs, five walls(two wood <br /> centrally located.A cluster of 14 studs is located in the center stud and three steel stud configurations)were studied as shown <br /> of the wall. This type of configuration is common among on Figures 8-a.through 8-e.These configurations represented <br /> whole-building energy modelers since it is easy to represent different options in installation of insulation.This analysis is <br /> any framing factor by adjusting the width of a single region. very important for situations where fiberglass batt insulation <br /> Figure 5 shows a configuration where studs are evenly is in use.For small cavities fiberglass bats have to be individ- <br /> distributed across the wall area.The wall shown in Figure 6 is ually measured, cut, and installed. Since it is a very labor- <br /> moreCrealistic. It contains several horizontal members, two intensive process, builders sometimes leave such small air- <br /> four-stud clusters, and two double-stud clusters. This wall <br /> / spaces without insulation. <br /> configuration is probably the best representation of current To enable comparisons between all wall configurations <br /> structural framing practice in residential buildings of the three presented onFigures 4 through 8,the following characteristics <br /> shown(Chin,Gupta 1997). were maintained in computer modeling: <br /> Buildings X 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.