My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12989346
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
14-XXXXXX
>
12989346
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 8:00:14 PM
Creation date
7/31/2025 4:34:49 PM
Metadata
Fields
Template:
Permits
Permit Address
16913 SILVER OAKS LN NE
Permit City
Silverton
Permit Number
555-14-007840-DWL
Parcel Number
061E29A 02300
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
555-15-001476-STR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES • <br /> 708.2 shall be protected in accordance with Sections 713.4.1 have anfrating/T rating of not less than l hour but not <br /> through 713.4.2.2. less than the required rating of the floor penetrated. J <br /> 713.4.1 Fire-resistance-rated assemblies.Penetrations of Exception: Floor penetrations contained and <br /> the fire-resistance—rated floor,floor/ceiling assembly or the located within the cavity of a wall above the floor <br /> ceiling membrane of a roof/ceiling assembly shall comply or below the floor do not require a T rating. <br /> with Sections 713.4.1.1 through 713.4.1.4. Penetrations in 713.4.1.2 Membrane penetrations. Penetrations of <br /> horizontal smoke barriers shall also comply with 713.5. membranes that are part of a horizontal assembly shall <br /> 713.4.1.1 Through penetrations.Through penetrations comply with Section 713.4.1.1.1 or 713.4.1.1.2. Where <br /> of fire-resistance-rated horizontal assemblies shall com- floor/ceiling assemblies are required to have a fire-resis- <br /> ply with Section 713.4.1.1.1 or 713.4.1.1.2. tance rating,recessed fixtures shall be installed such that <br /> the required fire resistance will not be reduced. <br /> Exceptions: <br /> Exceptions: <br /> 1. Penetrations by steel, ferrous or copper con- 1. Membrane penetrations by steel, ferrous or <br /> duits, pipes, tubes or vents or concrete or copper conduits,pipes,tubes or vents,or con- <br /> masonry items through a single fue-resistance- crate or masonry items where the annular space <br /> rated floor assembly where the annular space is is protected either in accordance with Section <br /> protected with materials that prevent the pas- 713.4.1.1 or to prevent the free passage of flame <br /> sage of flame and hot gases sufficient to ignite and the products of combustion.The aggregate <br /> cotton waste when subjected to ASTM E 119 or area of the openings through the membrane shall <br /> UL 263 time-temperature fire conditions under not exceed 100 square inches (64 500 mm2) in <br /> a minimum positive pressure differential of any 100 square feet(9.3 m2) of ceiling area in <br /> 0.01 inch(2.49 Pa) of water at the location of <br /> the penetration for the time period equivalent to assemblies tested without penetrations. <br /> the fire-resistance rating of the construction 2. Ceiling membrane penetrations of maximum <br /> penetrated.Penetrating items with a maximum 2-hour horizontal assemblies by steel electrical <br /> 6-inch(152 tam)nominal diameter shall not be boxes that do not exceed 16 square inches(10 <br /> limited to the penetration of a single fire-resis- 323 tam')in area,provided the aggregate area <br /> tance-rated floor assembly,provided the aggre- of such penetrations does not exceed 100 ( j gate area of the openings through the assembly square inches(44 500 mm2)in any 100 square <br /> does not exceed 144 square inches (92 900 feet(9.29 m') of ceiling area, and the annular <br /> mm') in any 100 square feet (9.3 m2) of floor space between the ceiling membrane and the <br /> area. box does not exceed'/a inch(3.2 tam). <br /> 2. Penetrations in a single concrete floor by steel, 3. Membrane penetrations by electrical boxes of <br /> ferrous or copper conduits,pipes,tubes or vents any size or type,which have been listed as part <br /> with a maximum 6-inch (152 tam) nominal of an opening protective material system for <br /> diameter,provided the concrete,grout or mor- use in horizontal assemblies and are installed in <br /> tar is installed the full thickness of the floor or accordance with the instructions included in the <br /> the thickness required to maintain the listing. <br /> fire-resistance rating. The penetrating items 4. Membrane penetrations by listed electrical <br /> shall not be limited to the penetration of a single boxes of any material, provided such boxes <br /> concrete floor,provided the area of the opening have been tested for use in fire-resistance-rated <br /> through each floor does not exceed 144 square assemblies and are installed in accordance with <br /> inches(92 900 mm2). the instructions included in the listing. The <br /> 3. Penetrations by listed electrical boxes of any annular space between the ceiling membrane <br /> material,provided such boxes have been tested and the box shall not exceed 4e inch (3.2 mm) <br /> for use in fire-resistance-rated assemblies and unless listed otherwise. <br /> installed in accordance with the instructions 5. The annular space created by the penetration of <br /> included in the listing. a fire sprinkler, provided it is covered by a <br /> 713.4.1.1.1 Installation.Through penetrations shall metal eschutcheon plate. <br /> be installed as tested in the approved fire-resin- 713.4.13 Ducts and air transfer openings. Penetra- <br /> tance-rated assembly. tions of horizontal assemblies by ducts and air transfer <br /> 713.4.1.1.2 Through-penetration firestop system. openings shall comply with Section 716. <br /> Through penetrations shall be protected by an 713.4.1.4 Dissimilar materials.Noncombustible pene- <br /> approved through-penetration firestop system trating items shall not connect o combustible materials l 4 <br /> installed and tested in accordance with ASTM E 814 beyond the point of frestopping unless it can be demon- <br /> or UL 1479,with a minimum positive pressure differ- strated that the fire-resistance integrity of the horizontal <br /> ential of 0.01 inch of water(2.49 Pa).The system shall assembly is maintained. <br /> 118 2010 OREGON STRUCTURAL SPECIALTY CODE. <br />