Laserfiche WebLink
Page 2 of 2 ESR-2201 <br /> WP-81 Acrylic and up to 1 quart of water (946.4 ml), then 4.9 Method of Repair: <br /> mixed until uniform consistency is achieved. The mixture <br /> results in a 4.5-gallon (17 L) batch. The base coat mixture The damaged area must be completely removed, including <br /> must be poured onto the lath at a rate of 40 square feet(3.68 the base coat and lath.New metal lath must be stapled to the <br /> square meters)per 4.5-gallon(17 L)batch.The minimum dry clean,dry substrate,and the system reapplied as described <br /> thickness of the base coat must be 0.142 inch(3.6mm).Prior in Sections 4.1 through 4.6 of this report.If substrate damage <br /> to the application of the slurry coat, the base coat must be occurs,the retention of the strength properties of the system <br /> smoothed with a trowel and allowed to cure until firm. must be investigated. <br /> 4.6 Slurry Coat: 5.0 CONDITIONS OF USE <br /> The slurry coat mature consists of one bag of TC-1 Cement, The WestCoat ALX System described in this report complies <br /> 1 gallon (3.78 L)of WP-81 Acrylic, and up to 1 quart(946.4 with, or is a suitable alternative to what is specified in, those <br /> ml)of water,mixed until uniform consistency is achieved The codes listed in Section 1.0 of this report, subject to the <br /> slurry coat mixture must be poured onto the cured base coat following conditions: <br /> at a rate of 100 to 150 square feet(9.2 to 13.9 square meters) <br /> per 4.5-gallon (17 L) batch, to result in a minimum dry 6.1 Materials must be manufactured and applied in <br /> thickness of the slurry coat of 0.063 inch(1.6 mm).The slurry accordance with this report, the applicable code, and <br /> coat must be smoothed with a trowel and allowed to cure until themanufacturerspublished installation instructions.In <br /> firm. the event of conflict between this report and the <br /> manufacturer's installation instructions, this report <br /> 4.6 Top Coat: governs. <br /> The SC-10 Top Coat must be applied over the cured slurry 6.2 The products are manufactured for WestCoat <br /> coat with a roller in one or two applications, for a total Corporation, in San Diego, California, under a quality <br /> coverage rate of 125 square feet per gallon(3.04 m2/L),to a control program with inspections by RADCO, Inc. (AA- <br /> minimum thickness of 6 mils(0.152 mm). The coating must 650). <br /> be allowed to cure until dry. <br /> 4.7 Class A Roof Covering over Plywood Deck: 6.0 EVIDENCE SUBMITTED <br /> When the WestCoat ALX system is applied over plywood Data in accordance with the ICC-ES Acceptance Criteria for <br /> substrate with all edges blocked and installed in accordance Walking Decks(AC39),dated March 2000(editorially revised <br /> with Section 4.0 ata maximum roof slope of/,inch per 1 foot October 2004). <br /> (2%slope),the system provides a Class A roof classification. 7.0 IDENTIFICATION <br /> 4.8 Wind Resistance: The TC-1,WP-81,and SC-10 products must be labeled with <br /> CInstallation must be limited to buildings with a maxmum the WestCoat name and the manufacturing address,the date <br /> height of 40 feet(12.2 m)above grade,in Exposure B areas of manufacture,the shelf Me and the lot number or production <br /> with a maximum 3secondgustbasicwind speed of 100 miles number.In addition to the above, the TC-1,WP-81,and SC- <br /> per hour(161 km/h),under the IBC and IRC;and a maximum 10 products listed in this report are labeled with the ICC-ES <br /> fastest mile basic wind speed of 80 miles per hour (129 report number(ESR-2201) and the name of the inspection <br /> km/h), under the UBC. The plywood and its attachment to agency(RADCO, Inc.). <br /> support framing must be adequate to resist the required wind <br /> load. <br /> L • <br />