Laserfiche WebLink
Technical Data Installation Recommendations <br /> Installation of CertainTeed ProRoe Type X <br /> Composition and Materials Applicable Standards and References Gypsum Boards should be consistent with <br /> Manufactured panel with gypsum core, ASTM C 840 methods described in the standards and <br /> L. encased in paper.Various additives are added Gypsum Association GA-216 references noted.Cutting should be from <br /> to the core to enhance fire resistive qualities. Gypsum Association GA-2l4 the face side of the boards for best results. <br /> ICC International Building Code(IBC) <br /> Surface Burning Characteristics <br /> CertainTeed PoRoc Type X Gypsum Board Decoration Notice <br /> has a Flame Spread rating of 15 and Smoke ProRoe Type X Gypsum Board accepts most The information in this document is subject <br /> Developed rating of 0,in accordance with types of paints,texture and wall covering to change without notice CertainTeed <br /> ASTM E 84,(UL 723,UBC 8-1,NFPA 255, materials.The surface shall be primed and assumes no responsibility for any errors that <br /> CANNLC-5102). sealed with a full-bodied latex primer before <br /> may inadvertently appear in this document. <br /> applying a final decorative material.This <br /> Fire Resistance will equalize the suction between the joint <br /> Fire resistance tests are conducted in compounds and the paper surface. <br /> accordance with ASTM E 119,(ANSI/UL 263, <br /> IBC 7-1,NFPA 251,CAN/ULC-S10I)and no For best painting results,all surfaces, <br /> warranty is made other than conformance to including joint compound,should be clean, <br /> the standard under which the assembly was dust-free and not glossy.If glossy paints are <br /> tested.Minor discrepancies may exist in the used,a thin skim coat of compound over <br /> values of ratings,attributable to changes in the entire surface,Level 5 finish,is <br /> materials and standards,as well as differences recommended to reduce highlighting or <br /> between testing facilities.Assemblies are listed joint photographing.This method is also <br /> as"combustible(wood framing)and recommended for areas of critical sidelighting <br /> "noncombustible-(concrete and/or steel of natural or artificial light sources. <br /> construction). <br /> A sealer application under wallpaper or <br /> For fire resistance ratings refer to the Gypsum other wall covering is also recommended so <br /> Association Fire Resistance Design Manual the board surface will not be damaged if the <br /> and UL Fire Resistance Directory-Vol. I. covering is subsequently removed during <br /> kw <br /> redecorating.Joint treatment must be <br /> thoroughly dry before proceeding with <br /> primer-sealer application and final decoration. <br /> ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: <br /> EXTERIOR: ROOFING • SIDING • WINDOWS • FENCE • DECKING • RAILING • MILLWORK • FOUNDATIONS • PIPE <br /> INTERIOR: INSULATION • WALLS • CEILINGS <br /> CertainTeed Corporation Professional:800-233-8990 1�a <br /> P.O. <br /> Box 860 Consumer: 800-782-8777 CertainTeed El <br /> Valley Forge,PA 19482 www.certainteed.com <br /> annawmn,ptannrs or performance of materials or n*®s mmmrmmw by an.mu 4 hadia described are derived from data obtained cacao controlled ten randiam n renainTeed Helms no.,enema.express or <br /> ` Implied as m sea<hanodnm.mopati or pnfmmmm.mtln any swaeons from such conditions In actual mmmsoa Certbirmi anus no responsibility for the effects of swam mn,®n. <br /> (`/ of m unman'am Ne naurc'Quaky made wAa sm6mm gummed?are oadamain of Cmmrmi Corporafion All new treelmults art the wmeny dare Pk or ifs aloft,and wo-d=Ww®. <br /> NO =E The mbamubn in this dmmet S subfed to dmge without notice.Cunmrod Loonies no mpeus fry for any errors that my Inadvertently appear In this docunsm <br /> 001/07 CmainTeed Corporation.Printed inUSA.CM-2337/56V1-200/ <br />