My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12986842
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
12-XXXXX
>
12986842
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 8:00:11 PM
Creation date
7/30/2025 11:57:10 AM
Metadata
Fields
Template:
Permits
Permit Address
16829 ABIQUA RD NE
Permit City
Silverton
Permit Number
555-12-00311
Parcel Number
061E20C 00601
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES <br /> lag members for a minimum distance of 4 feet 706.11 Ducts and air transfer openings.Ducts and air trans- <br /> (1220 mm)on both sides of the fire wall. fer openings shall not penetrate fire walls. <br /> 5. In buildings designed in accordance with Section Exception:Penetrations by ducts and air transfer openings <br /> 509.2,fire walls located above the 3-hour horizontal of fire walls that are not on a lot line shall be allowed pro- <br /> assembly required by Section 509.2, Item 1 shall be vided the penetrations comply with Section 716. The size <br /> permitted to extend from the top of this horizontal and aggregate width of all openings shall not exceed the lim- <br /> assembly. itations of Section 706.8. <br /> 706.6.1 Stepped buildings.Where afire wall serves as an <br /> exterior wall for a building and separates buildings having SECTION 707 <br /> different roof levels,such wall shall terminate at a point not <br /> less than 30 inches (762 nun) above the lower roof level, aff—PPM59# <br /> provided the exterior wall for a height of 15 feet(4572 nun) 707.1 General.Fire barriers installed as required elsewhere in <br /> above the lower roof is not less than 1-hour fire-resis- this code or the Fire Code shall comply with this section. <br /> tance-rated construction from both sides with openings pro- <br /> 707.2 Materials.Fire barriers shall be of materials permitted tected by fire assemblies having a fire protection rating of <br /> not less than'/a hour. by the building type of construction. <br /> Exception:Where the fire wall terminates at the under- 707.3 Fire-resistance rating.The fire-resistance rating of fire <br /> side of the roof sheathing,deck or slab of the lower roof, homers shall comply with this section. <br /> provided: 707.3.1 Shaft enclosures.The fire-resistance rating of the <br /> 1. The lower roof assembly within 10 feet(3048 mm) fire barrier separating building areasfrom a shaft shall corn- <br /> of the wall has not less than a 1-hour fire-resis- ply with Section 708.4. <br /> tance rating and the entire length and span of sup- 707.3.2 Exit enclosures. The fire-resistance rating of the <br /> porting elements for the rated roof assembly has a fire barrier separating building areas from an exit shall com- <br /> fire-resistance rating of not less than 1 hour. ply with Section 1022.1. <br /> 2. Openings in the lower roof shall not be located 707.3.3 Exit passageway.The fire-resistance rating of the <br /> 4111, within 10 feet(3048 mm)of the fire wall. fire barrier separating building areas from an exit passage- <br /> . 706.7 Combustible framing in fire walls.Adjacent combusti- way shall comply with Section 1023.3. <br /> ble members entering into a concrete or masonry fire wall from 707.3.4 Horizontal exit. The fire-resistance rating of the <br /> opposite sides shall not have less than a 4-inch(102 mm)dis- separation between building areas connected by a horizon- <br /> tance between embedded ends.Where combustible members tal exit shall comply with Section 1025.1. <br /> frame into hollow walls or walls of hollow units,hollow spaces 707.3.5 Atriums.The fire-resistance rating of thefire bar- <br /> shall be solidly filled for the full thickness of the wall and for a rier separating atriums shall comply with Section 404.6. <br /> distance not less than 4 inches (102 mm) above, below and <br /> between the structural members,with noncombustible mated- 707.3.6 Incidental accessory occupancies. The fire bar- <br /> als approved for fireblocking. rier separating incidental accessory occupancies from other <br /> 706.8 Openings.Each opening through afore wall shall bepro- spaces in the building shall have a fire-resistance rating of <br /> not less than that indicated in Table 508.2.5. <br /> tected in accordance with Section 715.4 and shall not exceed <br /> 156 square feet(15 m2), The aggregate width of openings at 707.3.7 Control areas. Fire barriers separating control <br /> any floor level shall not exceed 25 percent of the length of the areas shall have a fire-resistance rating of not less than that <br /> wall. required in Section 414.2.4. <br /> Exceptions: 707.3.8 Separated occupancies.Where the provisions of <br /> Section 508.4 are applicable, the fire barrier separating <br /> 1_Openings are not permitted in party walls constructed mixed occupancies shall have a fire-resistance rating of not <br /> in accordance with Section 706.1.1. less than that indicated in Table 508.4 based on the occupan- <br /> 2. Openings shall not be limited to 156 square feet(15 ties being separated. <br /> m2) where both buildings are equipped throughout 707.3.9 Fire areas.The fire barriers or horizontal assem- <br /> with an automatic sprinkler system installed in actor- blies, or both, separating a single occupancy into different <br /> dance with Section 903.3.1.1. fire areas shall have a fire-resistance rating of not less than <br /> 7069 Penetrations.Penetrations of that indicated in Table707.3.9.There barriers or horizon- <br /> fire walls shall comply f <br /> with Section 713. tat assemblies,or both,separating fire areas of mixed occu- <br /> pancies shall have afire-resistance rating of not less than the <br /> (' 706.10Joints.Joints made in or between fire walls shall com- <br /> ply highest value indicated in Table 707.3.9 for the occupancies <br /> v with Section 714. under consideration. <br /> 2010 OREQON STRUCTURAL SPECIALTY CODE t09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.