Laserfiche WebLink
• <br /> 13 <br /> The FAIAK' wallforms are shipped on 48"x36"pallets; each pallet containing entirely <br /> one type of wall form. A helpful feature of the Faswall system is that all wallforms are <br /> interchangeable dimensionally. This gives the installer options if he lacks a particular type of <br /> wallform for a given part of the build. For example,the AP unit can be used as a standard wall <br /> form, or a corner wall form(notching required)if necessary. <br /> NOTE: Wallforms are designed to be tilled with concrete and are not intended to stand <br /> alone as load bearing blocks. <br /> 2.0 R Value and U Values <br /> Wall Design R-Value* U-Value <br /> Concrete filled Faswall wall R-21 .048 <br /> with 3"mineral wool inserts, <br /> interior plaster,exterior stucco <br /> coating <br /> t Concrete filled Faswall wall R-25.5 .039 <br /> with 3"polyisocyanurate foam <br /> inserts,interior plaster, <br /> exterior stucco coating <br /> Concrete filled Faswall wall R-11.8 .085 <br /> with NO additional insulation. <br /> ♦Th <br /> ermal Mass Factor,although not calculated,adds substantial benefit <br /> 3.0 Designing with Faswall®Wall forms <br /> 3.1 General Design Principles <br /> The ideal Faswall design results in little to no cutting of the wallforms. Stack wallforms-insert <br /> rebar-fill with concrete-DONE. By following a few fundamental design rules you can achieve a <br /> 30%reduction in installation labor and eliminate cut wallform waste. <br /> ShelterWorks General Application and Technical Information(GATT)version 2.5 <br />