My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12983376
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
13-XXXXX
>
12983376
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2025 8:00:14 PM
Creation date
7/29/2025 2:43:37 PM
Metadata
Fields
Template:
Permits
Permit Address
5885 SKYLINE RD S
Permit City
Salem
Permit Number
555-13-02035
Parcel Number
083W17C 00400
Permit Type
Revision
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SPEC n SHEET WATERPROOFING 07 13 00 <br /> kj= ,, Grace Construction Products <br /> AM Hydroduct drainage composites should • ASIM D4751 Standard Test Method for Carefully read detailed precaution statements <br /> be promptly covered.Do not leave drainage Determining Apparent Opening Size of a on product labels and MSDS before use, or <br /> exposed to sunlight for more than 2 weeks. Geotextile mntad Grace Construction Products. <br /> Motor vehicles, construction equipment and • ASTM D4833 Standard Test Method for STOl%AGE&HANDING <br /> otter trades should not be avowed directly on Index Puncture Resistance of Geotextiles, Protect all materials from rain and physical <br /> the drainage composites. Geomembranes,and Related Roducts damage. Do not double stack pallets of <br /> Protect Bttuthene membranes from W or • ASTM 0.5385 Standard Test Method for membrane on the jabstte. Provide tarpaulin <br /> site damage immediately after installation or Hydrostatic Pressure Resistance of cover on top and all sides,clawing for ade- <br /> 24 hour flood test.Backfilling or installation of Waterproofing Membranes <br /> the wearing course should be completed as • ASTM E96 Standard Test Methods for Water quote ventilation. Store n.nnbrane where <br /> soon as possible. Vapor Transmission of Materials temperatures will not exceed 90 degrees F <br /> • ASIM E154 Standard Test Methods for Water (32 degrees C) for extended periods. In law <br /> 4.Technical Data Vapor Retarders Used in Contact with Earth temperature conditions, the membrane <br /> Under Concrete Slabs, on Walls, or as should be stored above 40 degrees F <br /> APPLICABLE STANDARDS Grouts Cover (5 degrees C) to promote good adhesion. <br /> ASIM International Store all products in a dry area away from <br /> • ASTM C366 Standard Test Methods for APPROVALS hgh heat, flames or sparks. Store only as <br /> Measurement of Ricans of SadvAch Cores • City of Los Angeles Research Report RR much material at point-of-use as required for <br /> • ASTM C336 Standard Specification for High 24386 each day's work. <br /> Solids Content, Cold Liquid-Applied • US. Department of Housing and Urban PREPARATORY WORK <br /> Bastomeric Waterproofing Membrane for Development(HUD)HUD Materials Release Surface Condition <br /> Use with Separate Wearing Course 628E Concrete must be smooth monolithic and <br /> • ASTM D412 Standard Test Methods for • Miami Dade,NOA 03-063004 free of voids. spoiled areas, loose substrate <br /> Vulcanized Rubber and Thermoplastic SPEtF1CA11ONS and sharp protrusions, dirt and debris, and <br /> Rubbers and Thermoplastic Eladomers- • American Railway Engineering Association must contain no visible coarse aggregate. <br /> Tension Chapter 29-2-4 Repair defects such as spalled or poorly con- <br /> PSTM DSAStandard Test Method for Water • Federal Construction Guide Specification soiidated areas. Use Bituthene Deck Prep <br /> Absorpfion of Mastics FCCS-07111 Surface Treatment to smooth and level rough <br /> • ASTM D882 Standard Test Method for Tensile • General Service Administration(GS GSA- concrete decks. Remove sharp protrusions <br /> Roperties of thin Plastic Sheeting PBS 07115 and form match lines. <br /> • ASTM D903 ofStandardAdhe tea Method for Peel • National Railroad Passenger Corporation <br /> or Stripping Adhesive Bonds airing <br /> (Amtrak)Section 7A2 Concrete must be cured a mirtimum of 7 <br /> • ASTM D1621 Standard Test Method for days <br /> Compressive Properties of Rigid Cellular US.• MASTERSPECe Section 07100 for normal structural concrete and 14 days for <br /> Mastics • US.Army Corps of Engineers LEGS-O7I11 lightweight structural corwete. If concrete is <br /> •• ASIM D1876 Standard Test Method for Peel US.Department of the Navy NFG597111 placed over a nanvented metal deck, the <br /> •Resistance of Adhesives(r-Feel Test) U.S. Department of Veterans Affairs required curing times doubled. Use form <br /> • ASTM D1970 Standard Specification forSelf- H-08-15edion 07113 release agents that will rot transfer to the con- <br /> Adhering Polymer Modified Bituminous PHYSICAL PROPERTIES crete.Remove forms as soon as possible from <br /> Sheet Materials Used as Steep Roofing Bihdhene waterproofing membranes conform below horizontal slabs to prevent entrapment <br /> Underlayment for Ice Dam Protection to the physical property and typical values list- of excess moisture.Excess moisture can lead to <br /> • ASIM D3767 Method A-Standard Ractikx ed in Tables 1 and 3.Hydroduct drainage an blistering of the membrane. Cure concrete <br /> for Rubber-Measurement of Dimension pasties conform to the physical property and with dear,resin based cuing compounds con <br /> • ASIM D3776 Standard Test Methods for typical values in Table 2. taming no oil,wax or pigment.Allow concrete <br /> Mass Per Unit Area(Weight)of Fabric to thoroughy dry fdlow ing ran. <br /> • ASIM D4491 Standard Test Methods for 5.Installation On masonry surfaces,apply a parge coat <br /> Water Pero roability of Geotextiles by SAHIy to rough concrete block and brick walls or <br /> Permittivity Bifufhene products must be openly handled. trowel-cut mortar joints flush to the face of <br /> pr <br /> • ASTM D4533 Standard Test Method for the concrete blocks. <br /> Trapezoid Tearing Strength of Geotextiles Vapors from the solvent based primer and C re time and drying time for concrete <br /> • ASTM D4632 Standard Test Method for R11stk,are harmful and flammable.For these and masonry surfaces may be reduced by <br /> Grab Breaking Load and Elongation of pr° - • We best (wadade intonation on using Bituthene Rimer B2. <br /> Geotextiles safe handling, storage, personal protection, TB4M32AlURE <br /> • ASTM D4716 Standard Test Method for health and environmental considerations has <br /> Constant Head Hydraulic TrarsrS&ily(In been gathered and is available on Material ' ApPty Bituthene System 4000 Membrane <br /> Mane Flow) of Geotextiles and Geotextile Safety Data Sheets (MSDS). Al risers stood only in dry weather when air and surface <br /> /Related Products acquaint themselves with this information. temperatures are above 25 degrees F <br /> ♦71 acrvra ...,Mw,av^..e.sawr nw...6.no-nwa..wnw.m...rwxre r....n...r.....m,m au..w a /J Reed'. ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.