Laserfiche WebLink
Bureau of Development Services <br /> Program Guide - Solar Water Heating and Photovoltaic Electric Generators <br /> 4111/ Installed on One or Two Family Dwellings <br /> Page 14 of 14 <br /> December 1, 2010 <br /> J Yes j No Is the roofing material metal,single layer wood shingle.or not more than two layers of composi- <br /> tion shylgle? <br /> J Yes j No Is the weight of the modules and racking less than 4.5 pounds per square foot? <br /> J Yes J No Is the module height less than 18 inches above the roof In accordance with section 305.4? <br /> For Standing Seam Metal Roofs Only(If not applicable please skip this section) <br /> J Yes J No Is the metal gauge 26 or heavier? <br /> J yes j No Clamp design:Are damps designed to withstand uplift of at least 115 pounds for damps spaced <br /> at 80 inches on center or less of at least 75 pounds for damps spaced at 48 inches on center or <br /> less? <br /> J Yes j No Is the spacing of the clamps as measured along the seam greater than or equal to 24'o.c.and <br /> less than 80'o.c.AND the spacing perpendicular to the seam not greater than 24'o.c.? <br /> J Yes J No Is the roofing panel width 18-inches or greater? <br /> J Yes J No Is the roofing panel attached with at least e10 screws at 24'o.c.? <br /> J Yes j No Is the roofing panels installed over minimum 1/2-inch nominal wood structural panels attached <br /> to framing with 8d nails at 8'o.c.at panel edges and 12"o.c.field nailing? <br /> If you have indicated"No"on any of these requirements above,the project may not be submitted <br /> using the prescriptive path. <br /> Fire Fighter Access and Escape <br /> Arr.c non-occupiedand escape pathways are not required when the array is located on a accessorywuctures that <br /> 1.110 is separated from occupied structures by a 6 foot minimum separation distance or by a mnimum twolwur fire rated <br /> assembly. <br /> General Requirements:For all other roof mounted systems,a minimum 36"wide pathway is required along three sides <br /> of the solar roof.located over a structurally supported area. My roof with a slope greater than 2:12 cal not use the <br /> bottom roof edge as a pathway. Pathways and solar panels shall be located outside 12"of the low point of a valley. <br /> If the army is greater than 150 feet it length or width,additional 38"wide intermediate pathways and cutouts are <br /> required. See code for details. <br /> If the roof has smoke and/or heat vents,a 36'pathway shall be provided to and around each vent. <br /> Exceptions to General Requirements: <br /> J Yes :I No Is the roof slope greater than 2:12? <br /> Oyes NO Is the array area 1,000sq ft or less? <br /> J Yes JNo Is the anay 150 feet or less in length or width? <br /> If you have Indicated"No"to any of the items above,exceptions do not apply,provide a simple plan conforrning <br /> with the general requirements. <br /> If you have indicated"Yes"to all of the items above,see below for reduced access and escape pathway require- <br /> ments. <br /> Is the army 25%or less of the roof area? J Yes J No <br /> • If Yes,a 12'pathway along each side of any horizontal ridge is required. <br /> • If No,a 12"pathway along each side of any honantal ridge is required and a minimum of one 36'pathway is re- <br /> quired from ridge to cave over a structurally supported area. <br /> Provide a simple plan showing conformance to the reduced access pathway requirements. <br /> As the property owner or authorized representative of the above listed property,I certify that I have verified the <br /> information provided above and that the roof rafters(if applicable to the project),meet the span requirements of <br /> Table 305A.1(Appendix 0)of the Oregon Solar Installation Specialty Code. <br /> Applicant name(please print) Signature Date <br /> dec oregen war mla40on cemst 01131/11 Pry of Portland Oregon-Bureau of Development Seances <br />