Laserfiche WebLink
7732 75TN PL SE, AUMSVILLE <br />94-02173 (55610) <br />December 5, 1994 <br />Page 1 <br /> <br />Marion County <br /> OREGON <br />COMMUNI¥¥ D[VI~LOPMI~N¥ <br />D£?ARTM£NT <br /> <br />Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the state of Oregon <br />1993 Edition One and Two Family Dwelling Specialty Code. <br /> <br />1. A COPY OF THE AppRoVeD PLANS sHALL BE KEPT ON THE SITE OF TEE BUILDING <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />The structural supports for decks, balconies, porches or similar <br />structures shall be pressure-treated wood to protect against decay. <br />(R-309.1) <br /> <br />Provide at least 1 square foot of underfloor ventilation for each 150 <br />square feet of crawl space area. The openings shall be covered with a <br />corrosion resistant wire mesh. At least one such opening shall be <br />provided within 3 feet of each corner of the building. (R-311.1) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />squar~ feet. (R-210.2) <br /> <br />Individual glazed areas in hazardeus locations ahall pass the test <br />(CPSC 16-CFR) requirements of Section N-20S.3 (safety glazing). <br />Hazardeus locations are considered as follows: <br />a. In doors and within 24 inches of a door. <br />b. Fixed and sliding panels of sliding-type doors (patio type). <br />c. Glazing in storm doors. <br />d. Glazing in doors and enclosures for hot tubs, whirlpools, saunas, <br /> steam rooms, bathtubs and showers. This includes glazing IN ANY <br /> PART OF A BUILDING WALL ENCLOSING TBESE COMPARTMENTS where the <br /> bottom edge of the glazing is less than 60" above the d~ain <br /> outlet. <br /> <br />This house plan uses Brace Panels (BP) to met the code rquirements for <br />lateral wall bracing. Insure that all BP's are located as indicated <br />on the plans. <br /> <br />"APPROVED" only when this ~heet is attached to plans <br /> <br /> <br />