Laserfiche WebLink
640 8TH ST, AUMSVILLE <br />January 28, 1995 <br />Page 2 <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The ~z~ow:sill :~gb~ s~all not be more <br />than 44 inches above the floor. ~ minimum ~t c(ea~ opening width <br />dimension shall be 20 inches. Th~ minim%~m net ~pen~g height shall be <br />24 inches. The minimum net clear opening area shall be at least 5~7 <br />square feet. (R-210~2) <br /> <br />10. <br /> <br />Individual glazed areas in hazardous locations shall pass the test <br />(CPSC 16-CFR) requirements of Section R-208.3 (safety glazing). <br />Hazardous locations are considered as follows: <br />a, In doors and within 24 inches of a door. <br /> <br />11. <br /> <br />This house plan uses a combination of Brace Panels (BP) and Alternate <br />Brace Panels (ABp) to met the code requirements for lateral wall <br />bracing. Insur~ that all BP's and A~P's ars located as indicated on <br />the plans and construoted aa show~ on the plans and the attached <br />8 l/2xll,, detail sheets. <br /> <br />12. <br /> <br />THE GYPSUM ER2%CE P/LNEL SHALL BE A MIMIMUM 0E 4' LONG Ai~D F~AVE ALL EDGES <br />OOF THE GYPSUM P~NELS BLOCKED. BRACE THE PANEL UP TO THE ROOF SHEATHING <br />WITH A~ Ai~GELED BP~ACE. SEE ATTACHEED SHEET FOR ONE APPROVED BRACING <br />METHOD. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br /> "APPROVED" only when this sheet is <br />attached to plans <br /> <br /> <br />