Laserfiche WebLink
695 9TH <br />January 27, <br />January 27, <br />Page 2 <br /> <br />aUMSWLLE <br />1995 <br />1995 <br /> <br />10. <br /> <br />11. <br /> <br />This house plan uses a combination of Erace Panels (EP) and Alternate <br />Brace Panels (ABp) to met the code requirements for lateral wall <br />bracing. Insure that all BP'S and A~P's are located as indicated on <br />the plans and constructed as shown on the plans and the attached <br />8 1/2xll" detail sheets. <br /> <br />This plan uses an ENGINEERED DESIGN to meet the lateral wall bracing <br />requirements of the FRONT WALL A~rD THE GAPdkGE, INSUHE T~AT ALL DETAILED <br />CONSTRUCTION REQUIRE~NTS SHOWN ON T~E PL~_NS ~ ON THE ATTACHED 8 <br />1/2"xll" ENGINEERING SHEETS ~-~E FOLLO~D. <br /> <br />In scissor trusses loose fill insnlation is not allowed when there is <br />less than 44 inches o~ headroom and/or =he interior ceilinq slope <br />exceeds 2 in 12, <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br /> "APPROVED" only when this sheet is <br />attached to plans <br /> <br /> <br />