My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1289865
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
95-XXXXX
>
Permit - 1289865
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2011 10:54:40 AM
Creation date
9/4/2003 9:49:31 AM
Metadata
Fields
Template:
Permits
Permit Address
170 SCOTT AV S
Permit City
Detroit
Permit Number
95-00595
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1301 Pine <br />Silverton, OR 97381 <br />May31,1995 <br /> <br />Log Home Supply <br />1754 Pine Street <br />Silverton, OR 97381 <br /> <br />Arm: Byron Miller <br /> <br />Re: Log Home, 170 Scott Ave, Detroit, OR <br /> <br />The following are recommended for this home: <br /> <br />Raymond Kaset, <br />Oregon Registered Professional Engineer <br />License No. 8108 <br /> <br /> 1. Three main logs for roof support -- lg" rain diameter at center of span with no more than <br /> 1" of taper in 6' of length, Blocking or straps must be provided to prevent rolling off <br /> the support. <br /> <br />2. Roof log support posts -~ 6" x 8". Max unbraced length is 6', <br /> <br />3. Roof decking, 2" nominal thickness, 6" flat on support logs. <br /> <br />4. Loft floor girder: 6" x 12", Support post (6" x 6") may be in stud walt as shown on plan. <br /> <br />5. Loft floor joist logs mad loft post, 8" diameter. <br /> <br />6. Main floor center support beam -- 6" x 10" <br /> Support and footing directly under each loft post (two). <br /> Minimum distance between supports for center beam is 6' 3". <br /> <br />7. Outside wall footings -~ 8" x 18" (816 lb per sq ft) <br />8. Footings under two loft posts -- 8" x 3' x 3' with 6" rebar grid. <br />9, Footings under other main floor support posts -- 8" x 2' x 2' <br />10. Porch framing (rafters) -- use 2 x 8 on 12" centers for long pieces, <br /> <br />1 I,Porch roof support girder 4" x 10 <br /> <br /> · , - ~,.,~GC~' :zt-.'c~.' / <br /> ....... Z~'Z;~_.-~ <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.