My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1289524
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1289524
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2011 2:11:25 PM
Creation date
9/4/2003 9:38:00 AM
Metadata
Fields
Template:
Permits
Permit Address
8734 SHAW SQ SE
Permit City
Aumsville
Permit Number
94-03784
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Boatwrigl~t Engineering Inc. <br />,.~. ~ 2613 12thSTSE SALEM. OREGON ~7302 <br /> ~,~ cJvil engineers ,. ~and survevors <br /> : ., -*o,i 363-9225 rFAX~ 363-1051 <br /> <br />September 22. 1994 <br /> <br />Mr. Fred Williams <br />1275 Wallace Road NW <br />Salem, Oregon 97304 <br /> <br /> PLAN REVIEW FOR STRUCTURAL ADEQUACY GARAGE/SHOP <br /> ELEVATED FOR BOB ROBELLOW <br /> <br />Dear Fred: <br /> <br /> I have reviewed the plans you prepared for the subject project and have made a number of <br />calculations to identify if the project as shown on the plans meets UBC criteria. <br /> <br /> In general the type and method of construction meets UBC criteria. <br /> <br /> I would recommend you consider the tbllowing modifications: <br /> <br /> 1) The 3/4" plywood subflooring needs to be T & G or solid blocked at all edges. Nail <br />3/4" plywood for diaphragm action ~ 10d common 4" OC edges, 12" OC interior supports and 2 <br />1/2" OC staggered at all botmdaries. <br /> <br /> 2) Place vertical reintbrcing #4 (7 12" OC at 3" from the inside wall race to centerline of <br />#4 bend and extend into the down footing inside the building at 3" clear from the bottom face. <br />Horizontal steel should be #4 ~ 12" OC, lap all ends 16" and all corners 16". <br /> <br /> 3) Reinforcing steel should be deformed bars with a yield strength of 40,000 psi. <br /> <br /> 4) All concrete should be 3000 psi compressive strength placed at 3" maximum slump. <br /> <br /> 5) A~chor bolts (1/2" x 8") spacing should be at 2' or less where the earth backfill is 6.5 <br />fcct or greater against the basement wall and 3' on centers where the backfill is less than 6.5 feet <br />deep. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.