My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1288679
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1288679
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2011 1:17:44 PM
Creation date
9/4/2003 9:23:25 AM
Metadata
Fields
Template:
Permits
Permit Address
5458 DUMORE DR SE
Permit City
Aumsville
Permit Number
94-04180
Parcel Number
082W13B 01200
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
5458 Dumore Dr. S.E.~ Aumsville ~ <br />94-4~80 / 9059231 ~ ~ ~ <br />November 18, 1994 <br />Page 1 <br /> <br /> Building Inspection - Dwelling Pla~ R~view <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1993 Edition One and TWO Family Dwelling Specialty Code. <br /> <br /> The following minimum concrete cover shall be provided for <br /> reinforcement~ <br /> <br /> a. Concrete cast against and permanently exposed to earth .... 3" <br /> <br /> b. Concrete exposed to earth or weather <br /> No. 6 through 18 bar ................................ 2" <br /> No. 5 bar, W31 or D31 wire, and smaller ......... 1-1/2" <br /> <br />2. Firestopping shall be provided in the following locations: <br /> A) In concealed spaces of stud walls, including furred spaces, <br /> at the ceiling and floor level; <br /> B) At all interconnections between concealed vertical and <br /> horizontal spaces such as occur at soffits, drop ceilings <br /> etc.; <br /> C) At openings around vents, pipes, ducts, chimneys and <br /> fireplaces at ceiling and floor level, with noncombustible <br /> materials. (R-402.7) <br /> <br />3 A minimum 3' X 3' landing shall be required on each side of an egress <br /> door. The floor Or landing shall not be more than 1-1/2" lower than <br /> the top of the threshold. (R-212 <br /> EXCEPTION: The landing on the exterior side of an exterior <br /> doorway shall not be more than 8-1/2" below the top of the <br /> threshold. <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />Engineer or Architect. For trusses manufactured by an approved <br />fabrication plant, have the design and layout drawings available at the <br />construction site for the framing inspection. All job site cutting or <br />modification of the roof trusses shall be clearly shown in the <br />engineer's design calculations and drawings. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />mm <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.