Laserfiche WebLink
'ILE:i <br /> <br />7760 75T~ PL SE, AUMSVILLE <br />94-04177 (5922S) <br />November 17, 1994 <br />Page 1 <br /> <br />Mario ,,County ...:'" . ..... <br />OREGON ..... <br />COMMUNITY DEVELOPMENT <br />DE?ARTMENI <br /> <br /> Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1993 Edition One and Two Family Dwelling Specialty Code. <br /> <br />1. A COPY OF THE APPNOVED PLP~NS S~ BE F~EPT ON THE SITE OF THE BUILDING <br /> OB WORK AT THE TIMB OF THE INSPECTION. (B-111.2) <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />A keyway in the footing is an acceptable method and will t~ansfer the <br />lateral loads, OR provide a 18 inch long No. 3 dowels extending 12 <br />inches from the footing into the wall, 4 feet on center, OR pour the <br />footing and stemwall at one time (monolithically). All wood le~t <br />permanently in contact with the foundation shall be FOUNDATION GRADE <br />WITH ~ CUT ENDS AND/OR SIDES TREATED with an approved wood <br />preservative. (R-310) <br /> <br />The structural supports for decks, balconies, porches or similar <br />structures shall be pressure-treated wood to protect against decay. <br />(R-309.1) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clea~ opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />Individual glazed areas in hazardous locations shall pass the test <br />(CPSC 16-CFR) requirements of Section R-208.3 (safety glazing). <br />Eazardous locations are considered as follows: <br />d. Glazing in doers and enclosures for hot tubs, whirlpools, saunas, <br /> steam rooms, bathtubs and showers. This includes glazing IN ANY <br /> PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS where the <br /> bottom edge of the glazing is le~s than 6O" above the drain <br /> outlet. <br /> <br />This house plan uses a combination of Brace Panels (BP) and Alternate <br />Brace Panels (ABP) to met the code rquirements for lateral wall <br />bracing. Insure that all BP'S and A~P'S are located as indicated on <br />the plans and constructed as shown on the plans and the attached <br />S 1/2x11" detail sheets. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />