My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1288510
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1288510
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2011 2:27:17 PM
Creation date
9/4/2003 9:20:42 AM
Metadata
Fields
Template:
Permits
Permit Address
7760 SUNNYBROOK LN SE
Permit City
Aumsville
Permit Number
94-04177
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SAND FILTER SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />March 16, 1993 <br /> <br />APPLICANT: KEN ALLEN <br />SITE NUMHER: 93-197 <br /> <br />FIVE ACRES, PARTITION <br /> <br /> Your site has been found suitable for a SD=ND FILTER ALTERNATIVE $EWAGB <br />DISPOSAL SYETEM. The following construction specifications shall apply to the <br />installation of your septic system. <br /> <br />1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />450 qallons per ..~. Based on soil conditions observed on this <br />site, the disDosal field will be sized at 45 lineal feet per 150 <br />qallons of projected daily sewage flow. A minimum of 135 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />On minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with equal distribution <br />with a minimum trench depth of 18 inches and a maximum trench <br />depth of 18 inches. There must be at least 6 inches of backfill <br />over the top of the gravel, measured from the natural ground <br />surface. <br /> <br />The sand filter system shall be designed and operated as per OAR <br />340-71-~90 through 340-71-30S. Detailed plans for the system must <br />be submitted prior to permit issuance. A building permit is <br />required if a site built concrete box is used as the sand filter <br />container. A pamphlet is available in our office which details the <br />requirements for a sand filter system. <br /> <br /> An effluent lift pump may be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS= <br /> Construct the drainfields on the highest part of the property within the <br /> immediate area of the northwesterly test pit. The easterly pit is <br /> slightly lower which will require a capping fill in conjunction with the <br /> sand filter drainfield. Use care not to disturb the natural soil <br /> conditions (topsoil) within the area of the drainfield sites. Filter <br /> fabric is required to cover the drainfield drainrock prior to backfill- <br /> ing. Observe all normal setback/separation distances. Refer to the <br /> enclosed setback list which outlines minimum separations between septic <br /> systems and other features. <br /> <br />THIS IS NOT A PEI~MIT TO INSTALL THE SEPTIC SYSTEM. DO NOT INSTALL THE SYSTEM <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY THIS OFFICE. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.