465 OLNEY, AU~SVILLE <br />94-04454 (59819) <br />December 10, 1994 <br />Page 1 <br /> <br />Marion Cou. nty :.. . <br /> ORI:GON ....... <br />COMMUNITY DI'-'V/LOPMI~NT ... * <br />DEPARTMENT <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1993 Edition One and Two Family Dwelling Specialty Code. <br /> <br /> ~ CoPY OF ~HE APPRf2VED PLANS SHALL BE KEPT ON THE STTE OF THE BUILDING <br /> OR WORK AT TEE TIME OF THE INSPECTION. (E-II1.2) <br /> <br />2. The grade away from foundation walls shall fall a minimum of 6 in. <br /> within the first 10 ft., except as restricted by lot lines where the <br /> fall will be a minimum of 6 in. regardless of the horizontal distance <br /> available. (R-301.3) <br /> <br />A keyway in the footing is an acceptable method and wilZ transfer the <br />lateral loads, OR provide a 18 inch long No. 3 dowels extending 12 <br />inches from the footing into the wall, 4 feet on center, OR pour the <br />footing and stemwall at one time (monolithically). All wood left <br />permanently in contact with the foundation shall be FOUNDATION GRADE <br />WITH aT3, CU~ ENDS A~D/OR SIDES TREATED with an approved wood <br />preservative, (R-310) <br /> <br />Every sleeping room ahall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net Opening height shall be <br />24 inches. ~he minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />The garage shall be completely separated from the residence and its <br />attic area by means of 1/2-inch gypsum board or equivalent al~plied to <br />the garage side. The door between the garage and residence shall be <br />equipped with solid wood doors not less than 1 3/8 inches in thickness <br />or 20-minute fire rated, or equivalent. (R-209.2) <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. All detectors shall be <br />interconnected such that the actuation of one alarm will actuate all the <br />alarms in the individual unit and shall provide an alarm which will be <br />audible in all sleeping areas. (R-215.1) <br /> <br />This plan uses an ENGINEERED DESIGN to me~t the lateral wall <br />bracing requirements of the ~H LIVING ROOM WAI~L ~N~ THE NORTH DINING <br />ROOM BAY WINDOW. INSUK~ THAT ~T~. DETAI~ED CONSTRUCTION <br />SHO~N ON THE P~S ~ ON THE ATTA~ED 8 1/2"x11" ENGINEERING SHEETS <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />