Laserfiche WebLink
210/220 lST ST., AUMSVILL~ <br />94-1268 (9053897) <br />April 19, 1994 <br />Page 1 <br /> <br />Marion County <br /> OREGON <br />COMMUNIYY DEVELOP~4ENT <br /> <br />~uildim~ Inspeetio~ - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1993 Edition One and Two Family Dwelli~]g Specialty Code. <br /> <br />10. <br /> <br />A copy of approved plans when ~equired by the building official shall be <br />kept on the site of the building or work at the time of inspection. <br />(R-iI1.2) <br /> <br />Approved numbers or addresses shall be placed on all buildings in such a <br />position as to be plainly visible and legible from the street or road <br />fronting the property. (UFC 10.208) <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />Drains shall be provided around all concrete or masonry foundations. <br />Perforated pipe or other approved[ systems or materials shall be <br />installed at or below the area to be protected and shall discharge by <br />gravity or mechanical means into an approved drainage system. (R-305.1) <br /> <br />Basement walls, foundation walls, and other vertical concrete exposed to <br />the weather shall have a minimum specified compressive strength of <br />3000 psi. Porches, carport slabs, garage floor slabs and steps exposed <br />to the weather shall have a minimum specified compressive strength of <br />3500 psi. Table No. (R-302.2) <br /> <br />12. <br /> <br />23. <br /> <br />Foundation walls shall extend at least 8 in. above the finished grade to <br />the foundation at all points. (R-304.2) (6 in. where pressure treated <br />sill plates ar~ used.) <br /> <br />Provide an access crawl hole to the underfloor space. The minimum size <br />opening required is 18 inches by 24 inches. (R-311.2) <br /> <br />42. <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with split <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br />level, except that if there is a door between levels then a detector is <br />required on each level. Mi1 det~eters shall be interconnected such that <br />the actuation of one alarm will actuate all the alarms in the individual <br />unit and shall provide an alarm which wall be audible in all sleeping <br />areas. (R-215.1) <br /> <br />46. <br /> <br />Bathrooms shall be provided with artificial light and an approved <br />mechanical ventilation system capable of producing a change of air every <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />